ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the

appliance from the electrical socket.

The hob has been inspected for LPG at a pressure of 30 mbar.

5.1

Removing the separable control panel

(models with

separable control panel)

1. Remove the knobs and the knob

guard tube “A” by pulling them up;

2. Use a crosshead screwdriver to

remove the screws and the two
cylindrical supports “B”;

3. Raise the left-hand side of the

control panel slightly and shift it to
the right to remove it completely;

4. In models with electric hotplate, the

body of the pilot light has to be
removed to free the control panel;

5. Raise the ignition crosspiece “D

and rest it on the other side.

5.2

Removing the hob

(models with integrated control

panel)

1. Remove the knobs, the

griddles, the burner caps, the
flame caps and the two rear
plugs;

2. Remove the screws “A

which fix the burner supports;

3. Raise the hob, sliding it off

the ignition plugs and/or the
thermocouples and the gas
tap rods;

4. Lift the ignition crosspiece

and rest it on the other side.