Appendix A — Wiring Requirements

●

●

●

●

25

Note the following cabling requirements before
connecting the equipment. If these limits (which
are the same ones that apply to our current
SPIRIT System) are exceeded, the ConnecT/R
may not work properly.

The total wiring length from the controller to
the SPIRIT Telephone cannot exceed a total

of 1000 feet of 24-gauge DIW (twisted-pair

copper) wire or 22-gauge D station wire,
plus 25 feet of 4-wire line cord.

The total wire length from the controller to
the telephone device cannot exceed a total of
1000 feet of 24-gauge DIW (twisted-pair
copper) wire or 22-gauge D station wire,
plus 25 feet of 4-wire line cord.

If the ConnecT/R is installed outside the
building where the controller is located, or
away from the building where the attached
SPIRIT Telephone is located (using exposed
wiring), In-Range/ Out-of-Building protec-
tors (IROB TII Model 371 or ITW Model

SP69073, AT&T order number 31304) must
be installed by a qualified technician.

Contact your AT&T representative for
additional information.

If the telephone device will be in a building
other than where the ConnecT/R is located,

a Block Protector must be installed by a
qualified technician (one Block Protector for
each "remote" telephone device). Order an
AT&T Model 4C1S (comcode 104386545).

In addition, you will need a Building
Entrance Protector, which can house up to

six 4C1S Block Protectors. Order Model

110ANA1-06 (comcode 105736482). Contact
your AT&T representative for additional
information.