Installation – SPX Cooling Technologies MARLEY 07-1126 User Manual

Page 7

Advertising
background image

7

Installation

Torque hub assembly bolts

11 according to the following table:

Fan Diameter

inches

Flange Type

Bolt Type

Bolt Torque

N·m

ft·lb

84" to 96"

Type 115

M16 cl. 8.8

230

169

M16 cl. A4-70

126

93

M16 cl. A4-80

168

124

108" to 168"

Type 190

M20 cl. 8.8

447

329

M20 cl. A4-70

246

181

M20 cl. A4-80

328

241

3––Hub into driveshaft installation (Figure 2).
• As for the hub with cylindrical bore, the hub is bored to attach
directly to the drive shaft.
Coat the output drive shaft with a thin layer of silicon grease.
If a space ring

10A is supplied, drive it into the drive shaft until it

comes in contact with the drive shaft shoulder.
Drive the hub with cylindrical bore into the drive shaft until it comes
in contact with the drive shaft shoulder (or space ring shoulder if
supplied).

Never power the drive shaft with special washer

16 and the retain-

ing bolt

17 missing or loose.

• As for the hub with tapered bushing hole, be sure drive shaft,
bushing and hub bore are not greased. Slide the bushing into the
drive shaft to your design position.
Position the hub core over the bushing taper; insert bushing screws
through the bushing flange into the threaded hole in the hub coupling;
torque bushing screws according to the following table:

Bushing Type

Screw Torque

N·m

ft·lb

Q1 and Q2

40

29

R1 and R2

40

29

Warning