Specifications – Knoll Systems HD282 User Manual

Page 26

Advertising
background image

26

7. Tighten the single screw.

8. Replace the lamp door by sliding the tabs into the tab bays and tightening the two screws.

9. Plug in the power cable, then press the Power button to turn the projector back on.

10. Reset the lamp hour timer.

Resetting the lamp timer

To reset the lamp age, simultaneously holding down the two Brightness buttons on the projector’s keypad
for 10 seconds.

Using the security lock

The projector has a security lock for use with a PC Guardian Cable Lock System. This lock needs to be
order from Knöll Systems. Refer to the information that comes with the lock for instructions on how to use it.

Specifications


Temperature Operating

50 to 95

° F (10 to 35° C) at 0 - 10,000 feet

Non-operating

-4

to

158

° F (-20 to 70° C) at 0 -20,000 feet


Altitude
Operating

0 to 10,000 feet (3,048 meters)

Non-operating

0 to 20,000 feet (6,096 meters)


Humidity
Operating

10 percent to 95 percent relative humidity, non-condensing

Non-operating

10 percent to 95 percent relative humidity, non-condensing


Dimensions

13.8

x

12.8 x 4.3”

(351W x 325L x 110H mm)


Weight

9.3 lbs. (4.24 kg) unpacked


Optics Focus Range

5 - 32.8 feet (1.5 – 10 meters)


Lamp Type

UHP lamp (dual watt: 200 and 250 watt)

Model

SP-Lamp-006


Input power requirements

100V-120V 4A 50/60 Hz

200V-240V

2A

50Hz