Service the Solenoid
NOTE:
Disassemble the faucet following the steps in the
″Disassemble the Faucet″ section.
Disconnect the wire connector and set the faucet body aside.
Remove the two mounting screws using a Phillips screwdriver.
Remove the solenoid unit.
Position the new solenoid unit. Make sure the O-rings are
properly positioned on the bottom of the solenoid.
Tighten the two mounting screws using a Phillips screwdriver.
Proceed to the
″Reassemble the Faucet″ section.
Screw
Solenoid Unit
O-Ring
O-Ring
O-Ring
Battery