Troubleshooting procedures – Kohler K-1460 User Manual

Page 15

Advertising
background image

Operating Sequence (cont.)

NOTE:

A built-in heater automatically helps to maintain the water temperature when the whirlpool is

running, as long as the water temperature does not exceed 104°F (40°C). The heater will disengage at
higher temperatures.

IMPORTANT!

Please refer to your Homeowners Guide for detailed instructions on the user keypad and

remote control.

Press Power to turn on the whirlpool. The whirlpool will start at medium flow.

Increase or decrease the water flow by pressing either the up or down arrow buttons on the keypad.
An indicator bar in the center of the keypad shows the water flow volume.

Adjust each jet for optimum air/water mixture. Turn the jet trim clockwise to reduce the air flow,
and counterclockwise to increase the air flow.

Make sure the slip cover is in place on the pillow, and the pillow is attached to the neckjet body.

With the whirlpool operating, rotate the outer ring until the neckjet icon is flashing. Press

″OK″ to

activate the neckjets. The neckjet pulsing action will start at medium speed.

Increase or decrease the neckjet pulsing action by pressing either the up or down arrow buttons on
the keypad.

To activate or deactivate different modes while the neckjets are operating, rotate the outer ring until
the desired mode is flashing and press

″OK″. (Example: To turn the heater off, rotate the dial until

the heater icon is flashing and press

″OK″).

Press

″OK″ while the neckjet mode is flashing to turn off the neckjets.

Press the Power On/Off button a second time to turn the whirlpool off.

NOTE:

A built-in timer automatically stops the pump and motor after approximately 20 minutes of

operation.

19. Troubleshooting Procedures

This troubleshooting guide is for general aid only. A KOHLER Authorized Service Representative or qualified
electrician should correct all electrical problems. For warranty service, contact your dealer or wholesale
distributor.

Troubleshooting the Whirlpool System

Symptoms

Probable Causes

Recommended Action

1.

User keypad does not

illuminate when power

button is pressed or outer

ring is rotated.

A.

No power to control.

A.

Check wiring and connect power.

B.

GFCI or RCD tripped.

B.

Reset GFCI or RCD.

C.

Wiring harness from user

keypad to control is loose,

disconnected or damaged.

C.

Check wiring for proper

connections. Replace wiring

harness if necessary.

D.

User keypad does not work.

D.

Replace user keypad.

E.

Control does not work.

E.

Replace control.

2.

Motor starts, but all jets

are not functioning.

A.

Jet is closed.

A.

Rotate jet trim counterclockwise to

open.

B.

Jet not installed correctly.

B.

Reinstall jet; check for O-ring

damage.

C.

Jets are blocked.

C.

Remove blockage.

3.

User keypad is

illuminated, but does not

respond to buttons or

outer ring.

A.

Control program is locked.

A.

Reset GFCI or RCD.

Kohler Co.

15

1019749-2-M

Advertising