Status Information Display and Settings

Displays the operating voltage, current consumption and internal temperature.
Additionally, changes the units for temperature or turns ON/OFF the demonstration.

Display type

Control knob

DISP switch

1

Slide the DISP switch towards INFO.

“INFO” appears on the display for 1 second.

2

Turn the control knob to change the display type in the following order.

Display

Information / Function

“VOLT”

Displays the operating voltage (V).

“CURRT”

Displays the current consumption (A).

“TEMP”

Displays the internal temperature (°C / °F).

“DEMO”

Sets demonstration display ON / OFF.

NOTE

• Temperatures lower than -22°F or -30°C are displayed as “-22F” or “-30C” respectively.
• Displayed information may differ from actual conditions.

Changing the units for temperature

Select °F (Fahrenheit) or °C (Celsius).

1 Turn the control knob, display “TEMP” and push the

control knob.

2 Turn the control knob, display “---F” (Fahrenheit) or “---C”

(Celsius) and push the control knob.

NOTE

The default setting is “---F” (Fahrenheit).

Turning DEMO ON/OFF

Turn the demonstration function ON to display “VOLT”, “CURRT” and
“TEMP” information. The demonstration display changes every five
seconds.

1 Turn the control knob, display “DEMO” and push the

control knob.

2 Turn the control knob, display “ON” or “OFF” and push the

control knob.

NOTE

The default setting is “OFF”.