4

Installation Clearance Requirements

The unit should be located on a firm and level surface. It is

important for the ice maker to be level in order to work properly. If
needed, you can adjust the height of the ice maker by rotating the
feet. See the “Leveling the Ice Maker” section.

A standard electrical supply (115 VAC only, 60 Hz, 15 A), properly

grounded in accordance with National Electrical Code and local
codes and ordinances is required.

IMPORTANT: Do not kink or pinch the power supply cord

between the ice maker and wall or cabinet.

1”

2/5”

1/5”

1/5”

Door Hinge

Back of unit

Top View

Side View

* This icemaker should be installed by a licensed

plumber only.

* To ensure proper service access and ventilation,

allow more 2/5” clearance at rear, and 1” at top and

1/5” at sides. The installation should allow the

icemaker to be pulled forward for servicing if

necessary.

* When installing the ice maker under a counter,

follow the recommended spacing dimensions shown.

Place electrical and water supplies and drain fixtures

in the recommended locations as shown.

* Choose a well ventilated area with temperatures

above 50°F and below 100°F.This unit MUST be

installed in an area protected from the elements,

e.g., wind, rain, water spray or drips.

* The icemaker should not be located next to ovens,

grills or other high heat resources.

* The ice maker requires a continuous water supply

with a minimum pressure of 0.05Mpa and a static

pressure not to exceed 0.8Mpa. The temperature of

the water feeding into the ice maker should be

between 41°F and 90°F for proper operation. The

ambient operational temperature should be between

50°F and 100°F. Operation outside these

temperatures may result in lowered production or

other adverse effects.