Specifications – Kenmore 300 Series User Manual

Page 33

Advertising
background image

33

Specifications

FIG. 45

Questions? Call The Kenmore Water Line 1-800-426-9345

Intermittent flow rate does not represent the maximum service flow rate used for determining the soften-
ers rated capacity and efficiency. Continuous operation at flow rates greater than the service flow rate
may affect capacity and efficiency performance.

These systems conform to NSF / ANSI 44 for the specific performance claims as verified and substantiat-
ed by test data.
The efficiency rating is only valid at the minimum stated salt dosage. These softeners were efficiency
rated acocording to NSF / ANSI Standard 44.

OTHER SPECIFICATIONS

MODEL 38306

MODEL 39306

Type of ion exchange material

high capacity

high capacity

Amount of resin (cu. ft.)

.78

.78

Rated Softening Capacity (Grains @ Pounds Salt Dose)

11,800 @ 2.3

25,300 @ 7.4

30,200 @ 12.5

11,800 @ 2.3

25,300 @ 7.4

30,200 @ 12.5

Efficiency Rating (Grains / Pound of Salt @ Minimum Salt Dose)

5120 @ 2.3

5120 @ 2.3

Rated Service Flow Rate (gpm)

7.5

7.5

Pressure Drop at Rated Service Flow Rate (psi)

14

14

Intermittent Flow Rate @ 15 psi (gpm)

7.9

7.9

Max. Drain Flow Rate (gpm) to Drain During Regeneration Cycle

2.0

2.0

Advertising