Make electrical connections - standard – Kohler Bath with Airjets 1199249-2-A User Manual

Page 7

Advertising
background image

3. Make Electrical Connections - Standard

NOTE:

The product model number is printed on a label on the blower side of the bath. This label also

identifies the electrical rating of the product. All baths come equipped with a wiring junction box and
are designed to operate between 220 V and 240 V at either 50 Hz or 60 Hz.

WARNING: Risk of electrical shock.

Make sure the power has been disconnected before

performing the following procedures.

WARNING: Risk of electrical shock.

Connect the blower to a properly grounded Ground-Fault

Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This will provide additional
protection against line-to-ground shock hazard. A 220-240 V, 20 A, 50/60 Hz dedicated circuit is
required.

IMPORTANT!

The load neutral is not used. There should be no connection to the load neutral terminal

on the Ground-Fault Circuit-Interrupter (GFCI) breaker. The green wire with the yellow stripe is the
equipment ground

and needs to be connected to the neutral bus in the main circuit breaker box.

NOTE:

The wiring harness includes an antenna for the optional remote control. Do not alter or damage

this antenna during installation.

Connect service to the junction box. The junction box contains blue, brown, and green with a yellow
stripe colored wires and a ground lug

Follow local electrical codes. Bond in accordance with national and local codes.

Control Power
Junction Box

Blue (L1)

Wire Connector

Ground
(Green with
Yellow Stripes)

From Control

Brown (L2)

Wire Connectors

Electrician to provide
suitable strain relief.

* Connections to be Made
at the Circuit Breaker

Typical Wiring Connection for North America

Control

Check Valve

Blower Motor Cord

Control
Power Supply

External Power

Field Wiring
(From Junction Box
to GFCI Breaker)

* Equipment Ground

* Line Neutral
(White
Curly Wire)

Neutral Bus
(In Breaker Box)

240 V

120 V

120 V

*L2

240 V

*L1

Typical Two-Pole
Circuit Breaker
with GFCI

Breaker Box

L2

L1

N

120/240 VAC Source

Bond in accordance with national and
local codes. Open bonding lugs are
located at the top of the junction box.

No Connection
(Load Neutral)

Kohler Co.

7

1199249-2-A