PERFORMANCE DATA SHEETS

Base Grille Water Filtration System

Model WF-L500/L500 capacity 500 Gallons (1893 Liters)

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psi (413.7 kPa). Temp. = 63°F
(17.2°C).

■

It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.

■

Using Replacement Cartridge L500 - Model WF-L500:
The concentration of the indicated substances in water
entering the system was reduced to a concentration less than
or equal to the permissible limit for water leaving the system
as specified in ANSI/NSF 42 and 53. The filter monitor system
measures the amount of water that passes through the filter
and alerts you to replace the filter. When 90% of the filter’s
rated life is used, the filter indicator light changes from green
to yellow. When 100% of the filter’s rated life is used, the filter
indicator light changes from yellow to red, and it is
recommended that you replace the filter. Use replacement
cartridge L500, part# 4392857. 2001 suggested retail price of
$29.95 U.S.A./$39.95 Canada.

■

The product is for cold water use only.

■

Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.

■

Refer to the “Assistance or Service” section for parts and
service availability or for the Manufacturer’s name, address
and telephone number.

■

Refer to the “Warranty” section for the Manufacturer’s limited
warranty.

■

Note that while the testing was performed under standard
laboratory conditions, actual performance may vary. Systems
must be installed and operated in accordance with
manufacturer’s recommended procedures and guidelines.

® NSF is a registered trademark of NSF International.

System tested and certified by NSF International against ANSI/NSF
Standard 53 for the reduction of Lead; and against Standard
ANSI/NSF 42 for the reduction of Taste and Odor, Chlorine Class I.

Contaminant
Reduction

Average
Influent
mg/L

Influent Challenge
Concentration

Product
Water
mg/L

Average %
Reduction

Max. Permissible
Concentration
mg/L

Max.
Effluent
mg/L

Min. %
Reduction

Lead: @ pH 6.5
Lead: @ pH 8.5

0.16
0.17

0.15 mg/L ± 10%
0.15 mg/L ± 10%

0.0024
0.0045

98.4
97.4

0.01
0.01

.005
.009

97
95

Substance Reduction

Min. Required %
reduction

Chlorine, Taste/Odor

2.0

2.0 mg/L ± 10%

0.14

93.0

≥

75%

N/A

N/A

Application Guidelines/Water Supply Parameters

Water Pressure
Water Temperature
Rated Service Flow

30 - 120 psig (207 - 827 kPa)

33° - 100°F (0.6° - 37.8° C)

0.5 gpm (1.9 Lpm)