Base grille water filtration system – KITCHENAID W10161714A User Manual

Page 21

Advertising
background image

21

Base Grille Water Filtration System

Model T1WG2L/T2RFWG2 Capacity 200 Gallons (758 Liters)

Model T1WG2/T2RFWG2 Capacity 200 Gallons (758 Liters)

This system has been tested according to NSF/ANSI 42/53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 42/53.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C).

■

It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.

■

Use replacement filter T2RFWG2, part #4396841. In Canada,
use replacement filter T2RFWG2, part #4396841B.
2007 suggested retail price of $39.99 U.S.A./$49.99 Canada.
Prices are subject to change without notice.

Model T1WG2L: Style 1 – Press FILTER to check the status
of your water filter. If the filter indicator light is yellow, order a
new filter. If the filter indicator light is red, it is recommended
that you replace the filter.

Style 2 – When the filter indicator reads 10%, order a new
filter. When the filter indicator reads 0%, it is recommended
that you replace the filter.

Model T1WG2: Change the water filter every 6 months
depending upon your usage. If the water flow to the water
dispenser or ice maker decreases noticeably before 6 months
have passed, replace the water filter more often.

■

These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.

■

The product is for cold water use only.

■

Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.

■

Refer to the “Assistance or Service” section for the
Manufacturer’s name, address and telephone number.

■

Refer to the “Warranty” section for the Manufacturer’s limited
warranty.

Application Guidelines/Water Supply Parameters

System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class II*; and against NSF/ANSI Standard 53 for the reduction of
Mercury, Benzene, Toxaphene, O-dichlorobenzene, and Carbofuran.

Substance Reduction
Aesthetic Effects

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Average
Effluent

Minimum %
Reduction

Average %
Reduction

Chlorine Taste/Odor
Particulate Class II

*

50% reduction
85% reduction

2.0182 mg/L
1333333 #/mL

2.0 mg/L ± 10%
At least 10,000 particles/mL

0.06 mg/L
6600 #/mL

**

0.0536 mg/L
2325 #/mL

97.03
99.51

97.34
99.83

Contaminant
Reduction

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Average
Effluent

Minimum %
Reduction

Average %
Reduction

Lead: @ pH 6.5***
Lead: @ pH 8.5***

0.010 mg/L
0.010 mg/L

0.1533 mg/L
0.1400 mg/L

0.15 mg/L ± 10%
0.15 mg/L ± 10%

0.0005 mg/L
0.0007 mg/L

0.0005 mg/L
0.0006 mg/L

99.67
99.50

99.67
99.57

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.0058 mg/L
0.0059 mg/L

0.006 mg/L ± 10%
0.006 mg/L ± 10%

0.0002 mg/L
0.0005 mg/L

0.0002 mg/L
0.0003 mg/L

96.54
91.57

96.54
94.92

Benzene

0.005 mg/L

0.0154 mg/L

0.015 mg/L ± 10%

0.0012 mg/L

0.0006 mg/L

92.22

96.34

O-Dichlorobenzene

0.6 mg/L

1.7571 mg/L

1.8 mg/L ± 10%

0.0250 mg/L

0.0066 mg/L

98.58

99.63

Toxaphene

0.003 mg/L

0.015 mg/L

0.015 mg/L ± 10%

0.001 mg/L

0.001 mg/L

93.33

93.33

Carbofuran

0.04 mg/L

0.0819 mg/L

0.08 mg/L ± 10%

0.0400 mg/L

0.0213 mg/L

51.13

74.00

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi

*

**

***

Class II particle size: 1 um to <5 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc.

® NSF is a registered trademark of NSF International.

Advertising