7

SPEAKER OUTPUT

SERVO

ΙΙ

SERVO

ΙΙ

POWER IN

FUSE(20A)

BATT

GND

FUSE(20A)

P.CON(REMOTE)

SPEAKER OUTPUT

20

20

SERVO

ΙΙ

SERVO

ΙΙ

-

+

Power and Speakers cable connection

Terminal cover

Battery

Ground cable (Commercially available part)

Battery cable
(Commercially available part)

Power control cable
(Commercially available part)

Subwoofer

Distribute the speaker cables and sigma
servo cables along the same paths.

Protective
Fuse

To prevent fire caused by a short in the wiring, connect a fusible link or breaker nearby the battery’s
positive terminal.

Wiring

• If a buzzing noise is heard from the speakers when the engine is running, connect a line noise

filter (optional) to each of the battery wire.

• Do not allow the cord to directly contact the edge of the iron plate by using Grommets.
• Connect the ground wire to a metal part of the car chassis that acts as an electrical ground

passing electricity to the battery‘s negative - terminal. Do not turn the power on if the ground
wire is not connected.

• Be sure to attach a protective fuse into the battery wire close to the battery. Use a protective fuse

having a capacity that is about 10 A higher than the maximum current drawn by the amplifier.

• Use vehicle-type (fire-resistant) power supply wiring wire for the battery wire and the ground wire.

The current capacity of the power supply wiring wire should be about 10 A higher than that of the
protective fuse capacity (which means about 20 A higher than the maximum current drawn by the
amplifier).

• When more than one power amplifier are going to be used, use a power supply wiring wire and

protective fuse of greater current-handling capacity than the total maximum current drawn by each
amplifier.

Power terminal

Connect to their respective terminals the power control wire, power supply wire, and ground
wire, all of which pass through the associated terminal cover. Once the connections are
complete, place the cover on the terminal section.

2WARNING

Maximum Current Drawn

Protective Fuse

Cross-sectional Area of Wiring

Wire (AWG)

28 A

40 A

×

1 [20 A

×

2]

5 mm

2

(AWG 10) or

greater

×

1

Example: One Power Amplifier Is Used

Round terminal (Large)

Round terminal (Small)

Round terminal (Medium)

50 A

25 A

25 A

25 A

25 A

Power control (REMOTE) lead terminal