Product data sheets – KITCHENAID Bottom-Mount Built-In Refrigerator User Manual

Page 16

Advertising
background image

16

PRODUCT DATA SHEETS

Base Grille Water Filtration System Model WF-LC400/LC400

Capacity: 400 Gallons (1514 Liters)
Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.

■

It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.

■

Model WF-LC400 The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400,
part# 4396164. 2002 suggested retail price of $39.95 U.S.A./
$49.95 Canada. Prices are subject to change without notice.

■

The product is for cold water use only.

■

■

■

■

Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before
or after the system.

■

Refer to the front cover or “Assistance or Service” section for
the Manufacturer’s name, address and telephone number.

■

Refer to the “Warranty” section for the Manufacturer’s limited
warranty.

Application Guidelines/Water Supply Parameters

Substance Reduction
Aesthetic Effects

Chlorine Taste/Odor
Particulate

U.S. EPA
MCL

N/A
N/A

Average
Influent

2.0 mg/L
610,000/mL*

Maximum
Effluent

N/A
N/A

Average
Effluent

0.04 mg/L
154/mL

Minimum %
Reduction

N/A
N/A

Average %
Reduction

98%
99%

NSF Test
Number

994707
994711

Contaminant
Reduction

U.S. EPA
MCL

Average
Influent

Maximum
Effluent

Average
Effluent

Minimum %
Reduction

Average %
Reduction

NSF Test
Number

Cyst
Turbidity

99.95%**
0.5 NTU

89,250/mL*
29 NTU

6/mL
0.12 NTU

2.3/mL
0.09 NTU

99.993%
99.59%

99.997%
99.69%

994710
994710

Lead

: @ pH 6.5

Lead

: @ pH 8.5

0.015 mg/L
0.015 mg/L

0.16 mg/L***
0.16 mg/L***

0.001mg/L
0.002 mg/L

0.001 mg/L
0.001 mg/L

99.4%
98.8%

99.4%
99.4%

994708
994709

Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Water Supply
Water Pressure
Water Temperature

City or Well

30 - 120 psig (207 - 827 kPa)

33° - 100°F (0.6° - 37.8° C)

*

**

***

Test requirement is at least 100,000 particles/ml of AC Fine Test Dust.

Cyst performance is % reduction based on NSF Standard 53.

Test requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water
conditions.

® NSF is a registered trademark of NSF International.