Mono operation, Zx amplifiers, Operation – Kicker ZX300.4 User Manual

Page 4

Advertising
background image

4

ZX AMPLIFIERS

AUTO

TURN ON

+12V DC AUDIO

OFFSET

XOVER

OFF LO

LO

HI

REMOTE BASS

INPUT

SPKR +

SPKR -

OUTPUT

INPUT

SENSITIVITY

OFF

ON

BASS

BOOST

GAIN

L

L

R

R

+

MONO OPERATION

minimum impedance of 2 ohms

signal in

signal out

woofer

ZX300.1

OPERATION

AUTO

TURN ON

+12V DC AUDIO

OFFSET

XOVER

OFF LO

LO

HI

REMOTE BASS

INPUT

SPKR +

SPKR -

OUTPUT

INPUT

SENSITIVITY

OFF

ON

BASS

BOOST

GAIN

L

L

R

R

Automatic Turn-On Selection: The ZX series offers three different automatic turn-on modes that can be
selected on the end panel; +12V, DC Offset, and Audio. Using either the DC Offset or Audio mode causes the
REM terminal to have +12V out for turning on additional amplifi ers.

Remote Turn-On: Set the switch to +12V to use the remote turn-on lead from your source unit. Run 18
gauge wire from the Remote Turn-On Lead on your source unit to the terminal labeled REM between the
amplifi er’s positive and negative power terminals. This is the preferred automatic turn-on method.

DC Offset Turn-On: If Remote Turn-On is not an option, the next best setting is DC Offset. The DC Offset
mode detects a 6V DC offset from the HI-Level speaker outputs when the source unit has been turned on.

• Signal Sense Turn-On: The Audio setting is the fi nal alternative for Automatic turn-on. This is a Signal Sense

turn-on method that detects the incoming audio signal from your source unit and automatically turns on the
amp. This turn-on method will not work properly if the input gain control is not set appropriately.

2010 ZX 300.1 400.1 500.1 750.1 RevC.indd 4