PRODUCT SPECIFICATIONS

MAXIMUM FUSE

RECOVERY RATE

MINIMUM

OR CIRCUIT

MODEL

IN GALLONS

GALS.PER HOUR

WIRE SIZE*

BREAKER

NUMBER

(LITERS)

DIA.

HEIGHT

@90

0

F Rise

120 Volt 240 Volt

(GAUGE)

SIZE (AMPS)

153.316040

6 (22.7)

14.250” (362) 15.375” (391)

7.5

1650

----

12

20

153.316050

10 (37.8)

16” (406) 18.25” (464)

7.5

1650

----

12

20

153.316060

19 (71.9)

18” (457)

24.9” (632)

7.5

1650

----

12

20

153.316070

19.9 (75.3)

16” (406) 31.62” (803)

7.5

1650

----

12

20

153.316331

30 (113.6)

22” (559)

30” (762)

7.5

1650

----

12

20

153.326060

19 (71.9)

18” (457)

24.9” (632)

9.1

----

2000

14

15

153.326070

19.9 (75.3)

16” (406) 31.62” (803)

9.1

----

2000

14

15

153.326331

30 (113.6)

22” (559)

30” (762)

9.1

----

2000

14

15

* Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.

Some compact models have labeled optional plumbing connections see below.

MODEL

NUMBER

STANDARD

SIDE COLD INLET

STANDARD

SIDE HOT INLET

STANDARD

SIDE T&P

MODEL HAS OPTIONAL

TOP COLD INLET

MODEL HAS OPTIONAL

TOP HOT OUTLET OR T&P

5.600

YES

YES

YES

YES, PLUGGED

YES, PLUGGED

5.6050

YES

YES

YES

NO

YES, PLUGGED

5.6060

YES

YES

YES

YES, PLUGGED

YES, PLUGGED

5.6070

YES

YES

YES

YES, PLUGGED

YES, PLUGGED

5.6

YES

YES

YES

NO

NO

153.326060

YES

YES

YES

YES, PLUGGED

YES, PLUGGED

153.326070

YES

YES

YES

YES, PLUGGED

YES, PLUGGED

153.326331

YES

YES

YES

NO

NO

DIMENSIONS

IN INCHES (mm)

TANK

CAPACITY

ELEMENT

WATTAGE

HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF

A LICENSED TRADESMAN IN THE FIELD INVOLVED.

PLUMBING AND ELECTRICAL WORK ARE REQUIRED.

Examine the location to ensure the water heater complies with the

“Facts to Consider About the Location” section in this manual.

5. For California installation this water heater must be braced,

anchored, or strapped to avoid falling or moving during

an earthquake. See instructions for correct installation

procedures. Instructions may be obtained from California

Office of the State Architect, 400 P Street, Sacramento,

CA 95814.

6. Massachusetts Code requires this water heater to be

installed in accordance with Massachusetts 248-CMR

2.00: State Plumbing Code and 248-CMR 5.00.