Direct Reading
These are measurement techniques
that can immediately indicate the
concentration of aerosols, gases, or
vapors by some means such as a dial
or meter or noting the color change of
an indicator chemical.

Colorimetric Detector Tubes
Several colorimetric, direct reading
detector tubes are useful for quick
assessments of airborne
contaminants associated with
photographic processing. A special
pump draws a specific volume of
room air through a detector tube. If
the contaminant is present, a color
change occurs along the length of the
tube that is directly proportional to
the concentration of the contaminant
in the air. Tubes are available for
acetic acid, sulfur dioxide, ammonia,
and many other gases and vapors.
The tubes are easy to use and
generally have an accuracy of ± 25%.
Other chemicals in the air may
interfere with the accuracy and
sensitivity of the tubes.

MEASUREMENT
TECHNIQUES

Threshold Limit Value-Short-

Term Exposure Limit (TLV-STEL):

The 15-minute TWA concentration
which should not be exceeded at any
time during a workday even if the 8-
hour TWA is within the TLV-TWA.
Exposure above the TLV-TWA up to
the STEL should not be longer than
15 minutes and should not occur
more than four times per day with at
least 60 minutes in between
exposures in this range.

Threshold Limit Value-Ceiling

(TLV-C):

The concentration that

should not be exceeded during any
part of the working exposure.

OSHA Limits vs ACGIH

Guidelines:

OSHA limits are legally

enforceable, whereas ACGIH limits
are guidelines. In most cases, the
ACGIH guidelines are the same or
lower than OSHA limits (there are a
few exceptions). When the values
are not the same, it is prudent to
follow the lower, more conservative
value.

Examples:

Air samples are sometimes collected
to evaluate potential worker
exposure levels for comparison to
published exposure standards or
guidelines. The purpose of the

Chemical

OSHA

PEL 8-hour

ACGIH

TLV 8-hour

Acetic acid

10 ppm

10 ppm

Ammonia

50 ppm

25 ppm

Formaldehyde 0.75 ppm

0.3 ppm
(ceiling)

Sulfur dioxide

5 ppm

2 ppm

METHODS OF
EVALUATION

THE PURPOSE OF
COLLECTING AIR
SAMPLES

measurement may vary depending
on whether you are interested in
short-term exposure, full shift
exposure, or the exposure incurred
during a specific step or process. The
measurements represent a sampling
of the actual working conditions at
the time of sampling. Generally, the
more sampling data that are
available for a certain job/process/
task under a variety of conditions,
the better understanding and
confidence you will have in the
exposure measurements during that
process. As illustrated in Figure 1,
actual exposure can vary
substantially during the day. In
some cases, full-shift monitoring
may be the goal while in others, the
goal may be to understand short-
term exposure.

Figure 1

Typical Exposure Scenario

Basic Definitions

Sensitivity or Precision: how
reproducible is the sampling
method.

Accuracy: how close to the true value
is the sampling method.

Avg.

8-hr

Actual

OSHA PEL

4pm

2pm

Noon

10am

8am

Concentration (ppm)