- 6 -

S VOLUME CONTROL. If necessary, you can adjust the

flow of water with adjusting screw. Decrease the flow by
turning the screw downward or increase the flow by turnĆ

ing the screw upward. The screw must be locked after
adjustment with the locknut.

S TRIP LEVER ASSEMBLY. When the trip lever arm is at

rest, rotor arm should not contact bottom of lift chain. If
necessary, bend trip lever arm downward to maintain

clearance.

S ROTOR ASSEMBLY. The rotor arm should rest on the

bottom of lift wire loop.

HOW TO SERVICE THE ROCHELLE AND
PALARRE TOILETS

The following instructions are used to replace the valve asĆ
sembly of the K-4859-EB Palarre and K-3385-EB

Rochelle.
Before beginning replacement procedures, turn off
water supply. Flush the toilet to drain water from tank.

REPLACING THE PLUNGER AND SEAT ASSEMBLY ON

EXISTING VALVE.

ă1. Turn off water supply. Remove cap assembly by unĆ

screwing the two cap screws. Remove plunger assemĆ

bly and old OĆring.

ă2. From inside the valve, remove old seat with a seat

wrench.

ă3. Thread in new seat. Insert new plunger subĆassembly

in order shown in Fig. #14. Assemble new OĆring to

cap and reassemble valve. Turn on water.

REMOVING OLD FLUSH VALVE

ă1. Turn off water supply. Disconnect float ball from float

rod.

ă2. Loosen locknut securing supply tube to tank.

ă3. Remove trip lever chain from trip lever.

ă4. Loosen screw in valve seat until seat clamp falls off.

ă5. Remove flush valve assembly.

INSTALLATION OF NEW FLUSH VALVE

ă1. Refer to Figs. #14 and #15. Insert lift wire through

hole in guide. Insert rotor arm into lift wire. Thread rotor

assembly into valve body.

ă2. Place long end of rim flush tube over rim flush opening

on valve.

ă3. Assemble rubber seat gasket onto seat.

ă4. Thread rubber gasket onto hush tube. Slide hush tube

over supply tube.

ă5. Set the seat clamp into center of tank outlet hole.

ă6. Refer to Fig. #15. Place valve into tank, making sure

that the rim flush tube is inserted into the rim flush supĆ

ply; supply tube is through open supply hole in bottom

of tank; and the clamp screw hole aligns with the openĆ

ing in the seat clamp.

ă7. With plastic collar on screw insert, thread in seat clamp

and tighten.

ă8. Attach flush ball to lift wire.

ă9. Assemble locknut to hush tube. Tighten locknut.

10. Insert float rod into float guide. Insert float ball.

NOTE: Adjust float rod to obtain the correct water level.
For proper timing, turn the timing screw downward to

decrease flow or upward to increase flow.

11. Reconnect flush valve to the water supply. Turn on supĆ

ply.

SERVICING THE FRENCH CURVE TOILET

SEAT (NEW STYLE, K-4653)

ă1. Locate and snap open the two hinged lids that cover

the bolt holes as shown in Fig. #16.

French Curve Seat Removal

Fig. #16

Hinged Lid
Washer

Nut

2. TO REMOVE SEAT. Unscrew the bolts and catch the

nuts from below. Pull seat and bolts away from toilet.

Remove the washers from the toilet.

3. TO REATTACH SEAT. Locate and snap open the two

hinged lids that cover the bolt holes. Slip bolts through

hinge from above. Slide washers onto mounting bolts.