Karcher NT 611 ECO M A User Manual

Page 14

Advertising
background image

Operating Instructions

NT 361 Eco M A / NT 611 Eco M A

English

23

Clean electrodes

!

Unlock and remove the suction

head

!

Clean electrodes

!

Replace the suction head and

lock it in place

Fault instructions

If a fault occurs (e.g. a torn filter),
the device must be switched off
immediately.
The fault must be remedied before
restarting.

The suction turbine does not
run
!

Check the cable, plug, fuse and

socket.

!

Switch on the machine.

The suction turbine switches off
!

Empty the container.

The suction turbine does not
restart following emptying of
the container
!

Switch the appliance off and

wait for 5 s, switch it on again
after 5 s.

!

Clean the electrodes as well as

the space between them.

The suction power decreases
— Remove the parts clogging up

the suction nozzle, the suction
tube, the Power Filter Clean
handle, the suction hose or the
flat pleat filter.

!

Change the paper filter bag.

!

Actuate the filter

cleaner: Power Filter Clean
several times at the handle.

!

Engage the filter cover

properly.

!

Replace the flat pleat filter.

Dust ejects when sucking
!

Check the proper mounting

position of the flat pleat filter.

!

Replace the flat pleat filter.

Automatic cut-out (wet suction)
defective
!

Clean the electrodes as well as

the space between them.

!

Constantly check fill level when

vacuuming electrically non-
conductive liquids.

Power Filter Clean switches
regularly
!

Detach blocked suction nozzle

or end of hose.

!

Stop continuous vacuuming

from liquid-containing container
or switch off - Power Filter
Clean – function (see chapter
on wet vacuuming).

!

Remove the parts clogging up

the suction nozzle, the suction
tube, the Power Filter Clean
handle, the suction hose or the
flat pleat filter.

!

Replace the flat pleat filter.

Advertising