Technical specifications, Notes – KoldFront PAC9000 User Manual

Page 4

Advertising
background image


Technical Specifications

Model PAC9000W
Electrical Power Supply

115 Volts / 60 Hertz

Rated Power Consumption During Cooling

See Label on Unit

Dehumidification Capacity

38 Pints per 24 Hours

Refrigerant R22
Refrigerant Load

500g

Fan Speeds

2

Airflow (H/L)

200

/

150

CFM

Noise Level

52dB(A)

Dimensions (HxWxD)

31.42"x14"x13.82"

Net Weight

55 Pounds

Timer 0.5-24

hours

Notes:

1) The above data were obtained in the following conditions:

Cooling conditions: Dry bulb/Wet bulb: 95/75°F according to European standard
EN14511-2004

2)

Operating limits for cooling:

Maximum ambient conditions: Dry bulb/Wet bulb: 100/80°

F

Minimum ambient conditions: Dry bulb/Wet bulb: 64/57°F

3

Advertising