Kohler Watertile Bodyspray 8002A User Manual

Page 4

Advertising
background image

4

1067580-AN2-D 14/11/11

Install the Finished Wall
1. Finish the wall, leaving the cutout 102

to 108 mm square.

2. Make sure that the dimension from the

front face of the elbow or tee to the

surface of the finished wall is a minimum

of 57 mm.

3. Thread the nipple into the elbow or tee

and hand tighten.

4. Measure the distance from the end of

the nipple to the surface of the finished

wall. Make sure that it is between 38

and 44 mm. If necessary cut the nipple

to the required length.

5. Remove the nipple and apply thread

sealant to the ends of the nipple.

6. Reinstall the nipple to the elbow or

tee.

7. Turn obn the water supply and flush out

the supply pipes.

Install the Waterway
1. Install the concealing plate into the

rough opening. The double ribs of the

leak shield should be facing up.

2. If the leak shield makes contact with the

elbow enlarge the hole in the back of the

leak shield to 32 mm.

3. Thread the adapter onto the nipple using

a 7/16” hexagonal wrench.

Important! be careful not to damage

the flow adapter. The concealing plate

should fit loosely at this point.
4. Align the groove in the waterway with

the double ribs on the leak shield.

5. Press the waterway into place over the

adapter.

6. Secure the waterway to the adapter with

the screw provided.

7. Make sure that the concealing plate

does not turn and is not loose.

Important! If the concealing plate is still

loose at this point shorten the nipple.

102 to 108 mm

102 to 108 mm

102 to 108 mm

Cutout

Nipple

Tee (or Elbow)

Finished Wall

Cutout

57 mm Min

7/16" Hex Wrench

Leak Shield

Concealing Plate

Adapter

Waterway

Screw