Replacement procedures, Changing the lamps – Kodak 7520 User Manual

Page 48

Advertising
background image

5-14

A-61140 January 1999

Replacement
procedures

Replacement procedures should be performed on an as-needed basis.
Components that need periodic replacement include the exposure
lamps and imaging guides.

Changing the lamps

The exposure system consists of two special, long-life fluorescent
lamps. The lamps slide in and out of the scanner for easy lamp
replacement:

•

Always replace both lamps at the same time. If both lamps are not
replaced, exposures may not be acceptable.

•

Use recommended lamps only. Other lamps may result in
unacceptable image quality.

Change the lamps every 500 hours, when required for error recovery, or
when image quality is poor.

WARNING: Make sure the lamps are cool before attempting to

remove them from the lamp socket holder.

To change the lamps:

1. Turn the power switch off.

2. Open the side access door.

3. Release the rear lamp cable connector from the scanner electrical

system.