Check/set distance of the magnetic sensor

The distance between the magnet

2

and the sensor

1

must be 2-4 mm,

otherwise malfunctions on the speedometer might occur.

This distance can be corrected by screwing the sensor

1

in or off.

mm x 3,14

KMH:
WS = mm x 3.14

MPH:
WS = (mm x 3.14) : 1.61

1

2

Wheel circumference with standard tires = 2205 mm

Replacing the headlight lamp/parking light lamp

Loosen both rubber bands and tilt the headlight mask to the front. Pull the
parking light lamp with holder

3

carefully out of the reflector. Pull

connector

4

off the headlamp and remove rubber cap

5

. Disengage retai-

ning clip and take the bulb out of the reflector. When changing the par-
king-light lamp, simply pull it out of the holder.

Insert a new lamp such that the noses

6

engage in the recesses

7

.When

doing so, do not touch the glass body of the lamp so that it remains free
from fat. Engage retaining clip, mount rubber cap and connector. If the par-
king-light lamp is to be replaced, simply insert it in the holder. Reinsert par-
king-light lamp together with the holder.
Engage the bottom end of the headlamp mask at the retaining pins and fix
the mask by means of the rubber bands.