Keating Of Chicago 022770 User Manual

Page 2

Advertising
background image

Ø29740

REVØ

ECO#1862

10/21/97

11-99

REPTHERM

REMOVAL AND REPLACEMENT OF THERMOPILE

FOR AA, AAHI & CM FRYERS

PART #022770*

REMOVAL:

1.

Unscrew and remove thermopile bulb from bracket.

2.

Unscrew thermopile capillarys from millivolt gas valve.

REPLACEMENT:

1.

Uncoil new thermopile carefully.

2.

Install connectors on the thermopile to the millivolt gas valve. (as shown in
wiring diagram.)
a. One connector goes to the TP screw on the millivolt control valve.
b. The other connector goes to the TH-TP screw on the millivolt control

valve.

NOTE: THESE ARE SCREW CONNECTORS

*THIS THERMOPILE PART #022770 REPLACES THE THERMOPILE PART #002567.

www.keatingofchicago.com

1-800-KEATING

S E R V I C E I N S T R U C T I O N S

Advertising