Kohler Six-Port Thermostatic Valve 1043183-5-D User Manual

Page 6

Advertising
background image

Troubleshooting (cont.)

Troubleshooting Table
Symptoms

Probable Cause

Recommended Action

5.

Fluctuating or reduced

flow rate. Valve is

functioning properly.

A.

Inlet/outlet fittings may be

blocked.

A.

Check the inlets and outlets for

blockage or debris. Clean the inlet

screens. Refer to the

″Clean the

Inlet Screens

″ section in the

Homeowners Guide.

B.

Water outlet pressure is low.

B.

Check that the flow rate is at or

above the minimum rate required.

Refer to the

″Specifications″ section.

C.

Fluctuating flow.

C.

Verify that the dynamic inlet

pressures are within specifications.

Refer to the

″Specifications″ section.

D.

If none of the above actions

correct the symptom, the valve

requires servicing.

D.

Contact your Kohler Co.

Authorized Service Representative.

6.

Blend temperature drift or

temperature cycling.

A.

Fluctuating water temperature.

A.

Check the inlet temperature

differentials and verify they are

sufficient. Refer to

″Specifications.″

B.

Hot water supply temperature

fluctuation.

B.

Check and make adjustments as

needed.

C.

Pressure difference greater than

5 psi (34.5 kPa) between the hot

and cold supply lines.

C.

Install pressure regulators to bring

supply lines within 5 psi (34.5 kPa)

of each other.

D.

If none of the above actions

correct the symptom, the valve

requires servicing.

D.

Contact your Kohler Co.

Authorized Service Representative.

7.

Maximum blend

temperature too hot or

too cold.

A.

Incorrect maximum temperature

setting.

A.

Refer to the

″User Interface

Homeowners Guide.

B.

If none of the above actions

correct the symptom, the valve

requires servicing.

B.

Contact your Kohler Co.

Authorized Service Representative.

8.

Continuous flow.

A.

System will not switch off.

A.

Turn off the water and power

supply and contact your Kohler Co.

Authorized Service Representative.

9.

Water leaking from the

valve.

WARNING: Risk of
electric shock and
personal injury.

Turn off

the main power and

water supply.

A.

Connections not secure.

A.

Check all connections. Make

adjustments as needed.

B.

Seals are worn or damaged.

B.

Order a seal service pack and

replace all seals.

C.

Internal leak.

C.

Unit requires overhaul. Contact

your Kohler Co. Authorized Service

Representative.

10.

Massage mode shuts

down but water continues

to run from

showerhead(s).

A.

Unequal flow rates between

valve outlets.

A.

Revise installation to have one

bodyspray per valve outlet. Use

bodysprays with the same flow

rate.

B.

Fluctuation of the inlet water

pressure.

B.

Install pressure regulators in the

supply lines.

C.

Pressure difference greater than

5 psi (34.5 kPa) between the hot

and cold supplies.

C.

Install pressure regulators to bring

supply lines within 5 psi (34.5 kPa)

of each other.

11.

Hot water only, the valve

shuts down.

A.

Hot and cold lines are reversed.

A.

Switch hot and cold water supply

connections. Verify the hot water

supply is connected to the

″H″ inlet

and the cold supply is connected to

the

″C″ inlet.

1043183-5-E