1071288-AN2-F 09/03/12

Install the Waterway

1.

Insert the concealing plate into the opening. The double ribs of the leak shields

should be facing up.

2.

If any of the leak shields make contact with an elbow, make sure

that you enlarge the hole in the back of the leak shield to

32 mm.

Install the Pipe Nipples
1.

Remove the pipe nipples.

Note! The minimum distance between the face of the tees/elbows and the

surface of the finished ceiling should be 57 mm. The measurement for typical

installations is 70 mm.

2.

Measure the distance from the face of the tees/elbows to the surface of the

finished ceiling. Make any adjustments as needed.

3. Install the nipples into the tee/elbows hand tight.
4. Measure the distance form the end of the nipples to the surface of the finished

ceiling. Make sure that the distance is at least 38 mm and no more than

44 mm.

5. If necessary, cut the G½” pipe nipples to length. Debur the ends.
6. Remove the nipples.
7. Apply thread sealant to the ends of the nipples and re-install the nipples to the

tees/elbows.

8. Run water through the system to flush out any dirt or debris.