Components, Operation, Pump replacement – KWC SUPRIMO Z.534.171.000 User Manual

Page 2: And specifications without prior notice, Service

Advertising
background image

Components






Operation

The pump is worked by a single full movement; by pressing the dispenser head downwards a 1/30 fl. Oz. of
liquid will be expelled. When first used it may be necessary to prime the pump with several movements.
Note: This dispenser is NOT designed for use with soaps which contain suspended particles. If these soaps
are used it will affect the working parts of the dispenser and will negate the warranty

.






Trouble Shooting

Symptom

Cause

Cure

No Soap is expelled when

PUMP not primed

Prime PUMP with several movements

Dispenser HEAD pressed

Soap BOTTLE Empty

Refill Bottle

Soap Congealed in PUMP

Lift DISPENSER BODY from

(Likely if dispenser has not been CONNECTOR and run hot water thro’

used for a number of weeks)

tube while operating PUMP

Hole in end of FLEXIBLE

Realign hole using a needle

TUBE not in line with SPOUT

FLEXIBLE TUBE is broken.

Contact Distributor

(Soap seen to leak from body)

PUMP is difficult to move

Soap Congealed in PUMP

Lift DISPENSER BODY from

(Likely if dispenser has not been CONNECTOR and run hot water thro’

used for a number of weeks)

tube while operating PUMP

PUMP is damaged

Replace PUMP (see Service Section)


Service

It is unlikely that any components will fail in normal use, but should it be necessary, parts are replaceable
in the assemblies illustrated and are available from your local KWC DISTRIBUTOR. Before attempting to
replace any parts it is important the instructions below are read and understood.


PUMP replacement

1. To replace the PUMP firstly remove assembled BODY, PUMP unit from the CONNECTOR.
2. Remove the TUBE from the base of the pump by holding BODY,PUMP unit firmly and pulling TUBE.
3. Unscrew the 3 screws securing the BOTTOM LOCATING RING to the body and pull the ring away.
4. Again holding the BODY firmly, remove the PUMP by pulling it from the internal PLUNGER.
5. Insert new PUMP by pushing it into the PLUNGER. It is important that the PUMP is pushed fully home
otherwise the dispensing action will be impaired and/or leakage may occur.
6. Replace the BOTTOM LOCATING RING and secure with the SCREWS, take care not to over tighten,
then push TUBE back into PUMP and lower assembled UNIT into CONNECTOR.

Failure to follow above instruction will cause damage to the internal flexible tube.

WE RESERVE THE RIGHT TO CHANGE PRODUCT

AND SPECIFICATIONS WITHOUT PRIOR NOTICE



Bottle

Connector
Assembly

Spacer

Washer

Dip Tube

Body and
Pump

Assembly

Advertising