background image

0.090> 2.3

roaring,

flickering flame



ideal operating range

0.050> 1.4



0.035> 0.95

weak, sooty flame



0.020> 0.5



____________________________________________________

1 2 3 4 5 6

Position of the carburetor knob

draft in mm water gauge

draft in inches water gauge



SECTION 5

Servicing

ANNUALLY:

*Remove catalyst and fire ring and inspect and clean out burn pot of any build-up or

debris.

*Check flue and clean out soot build-up.

*Clean out stove interior and drip pan.

*Lightly brush off catalyst and inspect for deterioration– replace if necessary.

*Check all gaskets: rope seal around door, window seal (check for loose glass– no need

to remove), access panel gaskets.

*Check oil tank for damage or leaks and clean or replace main tank filter.

*Check all lines and connections for leaks or deterioration.

*A draft reading should be taken for low– and high-fire before operation.


QUARTERLY:

*Turn stove off and allow to cool.

*Remove catalyst and clean out any carbon deposits from burner bottom and oil inlet

inside burner (may need to clean deposits more frequently if using #2 fuel).