PRODUCT DATA SHEETS

Base Grille Water Filtration System

Model WF-L200V Capacity 200 Gallons (757 Liters)

Model WF-NL120V Capacity 120 Gallons (454 Liters)

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).

■

It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.

■

Model WF-L200V: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge L200V /NL120V,
part #4396701. 2005 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.

Model WF-NL120V: Change the water filter cartridge every 6-
9 months. Use replacement cartridge L200V / NL120V, part
#4396701. 2005 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.

■

The product is for cold water use only.

■

Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.

■

Refer to the front cover or “Accessories” section for the
Manufacturer’s name, address and telephone number.

■

Refer to the “Warranty” section for the Manufacturer’s limited
warranty.

Application Guidelines/Water Supply Parameters

Substance Reduction
Aesthetic Effects

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Average
Effluent

Minimum%
Reduction

Average%
Reduction

Chlorine Taste/Odor
Particulate Class lll

*

≥

50%

≥

85%

1.9 mg/L
49333/mL

2.0 mg/L ± 10%
At least 10,000 particles/mL

0.07 mg/L
640/mL**

0.06 mg/L
312/mL

>75%
98.7%

>75%
99.0%

Contaminant
Reduction

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Average
Effluent

Minimum%
Reduction

Average%
Reduction

Lead:@ pH 6.5
Lead: @ pH 8.5

0.01mg/L
0.01mg /L

0.14 mg/L

†

0.15 mg/L

†

0.15 mg/L ± 10%
0.15 mg /L ± 10%

0.0014 mg/L
0.0069 mg/L

0.0011 mg/L
0.0042 mg/L

99.00%
95.40%%

99.21%
97.20%

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.0059 mg/L
0.0054 mg/L

0.006 mg/L ± 10%
0.006 mg /L ± 10%

0.0009 mg/L
0.0007mg /L

0.0004 mg/L
0.00043 mg/L

84.74%
87.03%

93.22%
92.03%

Benzene

0.005 mg/L

0.0157 mg/L

0.015 mg/L ± 10%

0.002 mg/L

0.00083 mg/L

87.26%

94.71%

p-dichlorobenzene

0.075 mg/L

0.210 mg/L

0.225 mg/L ± 10%

0.0005 mg/L

0.0005 mg/L

99.76%

99.76%

O-Dichlorobenzene

0.60

1.84

1.8 ± 10%

0.20

0.0418

89.13

97.73

Toxaphene

0.003

0.0143

0.015 ± 10%

0.0012

0.0010

91.60

93.00

Ethyl Benzene

0.70

2.00

2.1 ± 10%

0.40

0.085

80.00

95.75

1,2,4- trichlorobenzene 0.07

0.232

0.21 ± 10%

0.0041

0.0016

98.23

99.31

System tested and certified by NSF International against NSF/ANSI
Standard 53 for the reduction of Lead, Mercury, Benzene,
p-dichlorobenzene, O-Dichlorobenzene, Toxaphene, Ethyl Benzene,
1,2,4-trichlorobenzene and against NSF/ANSI Standard 42 for the
reduction of Chlorine Taste and Odor and Particulate Class III.

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 GPM (1.9 L/min.) @ 60 psi.

*

**

†

Class Ill particle size: > 5 to < 15 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

® NSF is a registered trademark of NSF International.

Advertising