Kidde KN-COPP-B-LS (900-0230) User Manual

Page 8

Advertising
background image

Whenever the alarm is operating, the green Power LED flashes every 30
seconds to indicate the unit is monitoring for CO. If the alarm senses
dangerous levels of CO, the red Alarm LED will flash and the alarm will
emit an audible alarm pattern.

6. Model KN-COPP-B-LS (with digital display)

Operating Characteristics

5. Model KN-COB-B-LS Operating Characteristics

Operating and Alarm Characteristics

Function

LED Display

Alarm Sound

Unit Status

Recommendation

Normal
Operation

Green LED
flashes every 30
seconds

None

Normal DC
operation (sensing
no CO) and with
good batteries

None

Carbon
monoxide
alarm

Red LED flashes
with beeps.

4 quick beeps,
5 seconds
silence,
repeating

Alarm condition.
Dangerous
concentrations of
CO detected

Refer to “What to do
When the Alarm
Sounds” (inside front
cover)

Low
battery

Red LED flashes
every 30 seconds

One quick
beep every
30 seconds

Batteries need to be
replaced

Replace all three AA
batteries

Error /
service
alarm

Red LED flashes
every 30 seconds

One quick
beep every
30 seconds

Unit is in error
condition

Error

Red LED
constantly on

Constant
alarm

Very low battery or
unit malfunction

Replace battery.
If condition continues,
unit has malfunc-
tioned. Replace
immediately. Unit will
not respond to CO

Normal
Test/Reset
function

Red LED flashes
with beeps.
Green and amber
LED’s on

4 quick beeps,
5 seconds
silence,
repeated once

Normal operation
when Test/Reset
button is pressed

CO not detected.
Alarm for test
purposes only

End of
unit life
indicator

Red LED flashes
every 30 seconds

One quick
beep every 30
seconds

End of unit life

Replace unit immedi-
ately. Unit will not
respond to to CO

The following table illustrates the possible digital displays, describes the
audible alarm patterns, and the recommended actions to take.

6. Model KN-COPP-B-LS (with digital display)

Operating Characteristics

When the unit is first powered up, the green Operate LED flashes once
every 30 seconds and the digital display will show three “eights” – indi-
cating the alarm is in the start-up mode. The three “eights” will remain
for approximately 30 seconds. Then, the alarm will display “0” and
begin monitoring the air for CO and will continue to do so as long as it
receives power.

This alarm will display a “0” if CO concentrations between 0 and 30
PPM have been detected within the last 15 seconds.

Operating and Alarm Characteristics

LCD Display Shows

Alarm Sound

Unit Status

Recommendation

A steady display of
CO concentration
from 30-999. Red

LED flashes with beep

4 quick beeps,
5 secs. silence,
repeating for 4
min.– then 4
quick beeps
every minute

Alarm condition.
Dangerous
concentrations of
CO detected

Refer to “What to do
When the Alarm
Sounds” (inside front
cover)

Brief “888” for
approximately 30
seconds

None

Self test when first
powered up

None – CO has not
been detected.
Numbers shown for
test purpose only

A random number
is displayed –
approximately 200

4 quick beeps,
5 seconds
silence,
repeated once

Test/Reset button is
pressed

None – CO has not
been detected.
Numbers shown for
test purpose only

Steady “0”
displayed, dot flash-
ing every 5 seconds,

Green LED flashes every 30 secs.

None

Normal DC
operation with
good batteries
(sensing no CO)

None

“Lb” flashes alter-
nately with any
number, Red LED

flashes every 30 seconds.

One quick beep
every 30 seconds

Batteries need to
be replaced

Replace all three AA
batteries immediately

“Err” displayed

One quick beep
every 30 seconds

Unit is Error condi-
tion

Replace batteries.
If “Err” (or blank
display) continues,
unit has malfunc-
tioned. Replace
immediately. Unit will
not respond CO

Display is blank

Constant alarm

Unit malfunction

Number from 11-
999 displayed.

None

Peak Level Memory
activated. Highest
concentration of
CO detected is dis-
played

Refer to following
section for informa-
tion regarding Peak
Level Memory

“End” displayed.
Red LED flashes
every 30 seconds

One quick beep
every 30 seconds

End of unit life

Replace unit immedi-
ately. Unit will not
respond to CO.

The problems listed above are under normal operating conditions. Other
“Err” conditions could exist. If you should have any questions regarding
display conditions, call our Consumer Hotline.

Advertising