A-9

INSTALLATION

COMMANDER 500

A-9

CONNECTION OF AN LN-23P

WIRE

FEEDER TO THE COMMANDER 500

•

Shut the welder off.

•

Connect the LN-23P per instructions on the appro-

priate connection diagram in the DIAGRAMS sec-
tion. (NOTE): When connecting an LN-23P to the
Commander 500, a K350-1 adapter kit must be
used.

•

Set the

“

WIRE FEEDER VOLTMETER

”

switch to

“

-

”

.

•

Set the

“

SELECTOR

”

switch to

“

CV-WIRE

”

position.

•

Set the

“

WELDING TERMINALS

”

switch to

“

REMOTELY CONTROLLED

”

.

•

Set the ARC CONTROL to desired crispness. SOFT

for MIG - CRISP for Innershield.

•

Set the

“

IDLE

”

switch to the

“

HIGH

”

position. If you

are using an LN-23P with the K350-1 adapter kit, the
electrode is not energized until the gun trigger is
closed.

CONNECTION OF AN NA-3 AUTOMATIC
WELDING SYSTEM TO THE COMMANDER
500

For connection diagrams and instructions for connect-
ing an NA-3 Welding System to the Commander 500,
refer to the NA-3 Welding System instruction manual.
The connection diagram for the LN-8 can be used for
connecting the NA-3.

CONNECTION OF AN LN-742 TO THE
COMMANDER 500

•

Shut the welder off.

•

Connect the LN-742 per instructions on the appro-

priate connection diagram in the DIAGRAMS sec-
tion.

•

Set the

“

WIRE FEEDER VOLTMETER

”

switch to

either

“

+

”

or

“

-

”

as required by the electrode being

used.

•

Set the

“

SELECTOR

”

switch to the

“

CV-WIRE

”

posi-

tion.

•

Adjust the

“

ARC CONTROL

”

knob to desired

Crispness. SOFT for MIG and CRISP for Innershield.

•

Set the

“

WELDING TERMINALS

”

switch to the

“

REMOTELY CONTROLLED

”

position.

•

Set the

“

IDLE

”

switch to the

“

AUTO

”

position. When

not welding, the Commander 500 engine will be at
the low idle speed.