Copper-Fin

®

Boiler Dimensions & Specifications

CBN-07

(Replaced CBN-06 3/10)

FG-10M-5/11-Printed in U.S.A.

Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000

www.Lochinvar.com

Standard Features

81% Thermal Efficiency

Electronic Temperature Control

Fan Assisted Combustion

Sealed Combustion Chamber

Stainless Steel Burners

Low NOx Operation Exceeds the most

Stringent Air Quality Requirements

ASME Copper Finned Tube

Heat Exchanger

160 psi Working Pressure

Gasketless Heat Exchanger Design

Pump Relay w/ Delay

Down Stream Test Valve

Referenced Gas Valves

Loch-Heat Ceramic Tile

Combustion Chamber

Hot Surface Ignition

Adjustable High Limit w/ Manual Reset

ASME Pressure Relief Valve

Temperature & Pressure Gauge

Flow Switch

24 Volt Control System

BMS Terminal Strip

Combustion Air Filter

Freeze Protection

10 Year Limited Warranty on Heat

Exchanger (See warranty for details)

Optional Equipment

Alarm Bell

Contacts on any Failure

Contacts for Air Louvers

Cupro-Nickel Heat Exchanger

High & Low Gas Pressure Switch

w/ Manual Reset

Outdoor Reset Control

Manual Reset Low Water Cut-Off

w/ test

Stack Frame

MP

2

Sequencer

Available Firing Systems

M9

Hot Surface Ignition with

Electronic Supervision (Standard)

M13 GE

GAP/FM/CSD1

M7 California

Code

Venting

Outdoor Vent Cap

Registered under U.S. Patent # 5,989,020

For Ease In Ordering

By Model Number

C B N 0 4 9 7 M 9

MODEL

Btu/hr

INPUT

This boiler is a 495,000 Btu/hr,

natural gas Copper-Fin.

It has M9 firing controls

NAT. GAS

FIRING

CONTROLS

Copper-Fin Heating Boiler

Dimensions & Spec i fi ca tions

Input

Heating

Net

Model Max Thermal Capacity I=B=R

Gas Vent Shipping

Number MBH Efficiency MBH

MBH

A

B

C

D

E

F

G Conn. Size Weight

CBN0497

495

81%

401

349

31-1/2” 45-1/4” 22-1/4” 12-1/2” 9-1/2”

22-3/4” 29-1/2” 1-1/4”

6”

440

CBN0647

645

81%

522

454

31-1/2” 56-3/4” 22-1/4” 12-1/2” 9-1/2”

28-1/2” 29-1/2” 1-1/4”

8”

510

CBN0747

745

81%

603

524

31-1/2” 64”

22-1/4” 12-1/2” 9-1/2”

32”

29-1/2” 1-1/4”

8”

550

CBN0987

985

81%

798

694

36”

48-1/4” 33-1/2” 15-3/4” 8-1/2”

8-1/2” 33-3/4” 2”

10”

845

CBN1257

1255

81%

1,017

884

36”

58-1/2” 33-1/2” 15-3/4” 9-1/2”

10-1/2” 33-3/4” 2”

12”

905

CBN1437 1435 81%

1,162 1,010 36” 68-3/4” 33-1/2” 15-3/4” 10-1/2” 10-1/2” 33-3/4” 2”

12” 1050

CBN1797 1795 81% 1,454 1,264 36” 82-1/4”

33-1/2” 15-3/4”

11” 11” 33-3/4”

2” 14” 1193

CBN2067 2065 81% 1,673 1,455 36” 92-1/2”

33-1/2” 15-3/4”

11” 11” 33-3/4”

2” 14” 1350

Notes: Change ‘N’ to ‘L’ for LP gas models.

Water connections for models CB 0497-747 are 2” NPT on 6-1/2” centers.

No deration on LP models.

Water connections for models CB 0987-2067 are 2-1/2” NPT on 11-1/4” centers.

Performance data based on manufacturer test results.