Setting the switch selectable operating modes, Operation & adjustment instructions, Figure 14 settable switches location – Linear J-S User Manual

Page 16: Changing the switch selectable operation modes, Motor control board, High voltage o pe n, Stop close open

Advertising
background image

Changing the Switch Selectable Operation Modes

The following modes are selected by setting the on-board dip
switches, Figure 14 at right shows where the switches are
located on the operator control board. For each Operational
Mode, the switches are set to either ON or OFF according to the
table at right below. For all the modes, if an approved
entrapment protection (EP) reversing device as described on
page 3 of this manual is attached to the input labeled “Photo”, it
will function as noted. Once an approved EP device is
recognized by the control board it is monitored for correct
operation. If the device becomes inactive then the mode will
default to constant pressure activation for close regardless of the
dip switch setting. In order for any of the Momentary Contact
to Close operation modes (B2, TS, T) to become active an
approved Entrapment Protection (EP) Reversing device (see
Page 3) must be properly installed and connected to the
operator. The switches must be set to one of the six Operational
Mode combinations for the operator to function. It order for the
NO (Normally Open) Reverse or NC (Normally Close) Reverse
inputs to function, you must first install an operational approved
Entrapment Protection (EP) Reversing Device.

C2 Operation (Factory default)
Open Button: Momentary activation; open override of closing
door.
Close Button: Constant activation, door will stop when button is
released.
Stop Button: Momentary activation; stops open, close or reverse
action.
Single Button: Momentary activation to open; open override of
closing door.
EP Reverse (Photo Input): Momentary activation will reverse a
closing door, reverse to full open (ignores mid-stop) unless
stopped by stop pushbutton input.
Mid-Stop: Activation stops an opening door; momentary contact
of open button at mid stop will restart door to full open position;
if door is moving open, constant pressure on open button will
bypass mid-stop.
Auto Close Timer: N/A.

B2 Operation
Open Button: Momentary activation; open override of closing
door.
Close Button: Momentary activation.
Stop Button: Momentary activation; stops open, close or reverse
action.
Single Button: Momentary activation to open; open override of
closing door, closes door from mid-stop or open limit.
EP Reverse (Photo Input): Momentary activation will reverse a
closing door, reverse to full open (ignores mid-stop) unless
stopped by stop pushbutton input.
Mid-Stop: Activation stops an opening door; momentary contact
of open button at mid stop will restart door to full open position;
if door is moving open, constant pressure on open button will
bypass mid-stop.
Auto Close Timer: N/A.

D1 Operation
Open Button: Constant activation; open override of closing
door.
Close Button: Constant activation, door will stop when button is
released.
Stop Button: Momentary activation; stops open, close or reverse
action (not required).
Single Button: N/A.
EP Reverse (Photo Input): Momentary activation will stop a
closing door.
Mid-Stop: Activation stops an opening door; after the door stops
at the mid stop, constant contact of open button at mid stop will
restart door to full open position.
Auto Close Timer: N/A.
E2 Operation (roll-back)
Open Button: Momentary activation; open override of closing
door.
Close Button: Constant activation, door will reverse to full open
(ignores mid-stop) when button is released.
Stop Button: Momentary activation; stops open, close or reverse
action.
Single Button: N/A.
EP Reverse (Photo Input): Momentary activation to reverse a
closing door, reverse to full open (ignores mid-stop) unless
stopped by stop pushbutton input.

C

D

OMC

B

2

00

5

EDGE

RADIO

c.

p

. AL

LSTA

R CO

RP

.

P4

24V

S1

R58

R56

R55

R54

R45

R46

R53

PCB

1

12

69

5 REV

B T

SL

K

K2

K4

K3

K5

K6

CO

M

OL

S

C

L

S

CO

M

HIGH VOLTAGE

O

PE

N

MO4

MO3

MO2

MO1

ILK

24V

COM

VCC

FRA

COM

24V

RM1

RM2

RM3

VCC

COM

P7

R8

R24

C12

TB1

STATUS

LD4

OFF

S4
S3
S2
S1

C25

R94

R87

R38

R22

R10

P5

PB1

PB2

PB3

R49

C6

R93

R90

U5

R62

R61

R60

R5

R25

R9

R23

R51

R19

R17

R13

R20

R18

R14

STOP

CLOSE

OPEN

R7

R6

R16

R15

R11

R12

POWER

C24

R85

U1

C2

R

O

1

D8

U4

C

11

R

30

R

26

R

29

C3

C1

C8

R47

R84

R95

SW1

R83

R82

R33

R34

R2

R3

R4

C21

R21

D2

R65

C10

D3

C9

TR4

TR2

R52

C14

TR1

R48

C13

TR3

R89

Q1

C7

D1

D12

R28

R27

C16

LD3

LD2

P2

P3

R1

C30

P1

R31

P6

R57

COM

CL

O

S

E

ST

OP

NO

R

E

V

NC

RE

V

PH

O

T

O

COM

SINGL

E

IL

O

C

K

24

V

A

C

COM

MOTOR CONTROL BOARD

C

D

OMC

B

2

00

5

EDGE

RADIO

c.

p

. AL

LSTA

R CO

RP

.

P4

24V

S1

R58

R56

R55

R54

R45

R46

R53

PCB

1

12

69

5 REV

B T

SL

K

K2

K4

K3

K5

K6

CO

M

OL

S

C

L

S

CO

M

HIGH VOLTAGE

O

PE

N

MO4

MO3

MO2

MO1

ILK

24V

COM

VCC

FRA

COM

24V

RM1

RM2

RM3

VCC

COM

P7

R8

R24

C12

TB1

STATUS

LD4

OFF

S4
S3
S2
S1

C25

R94

R87

R38

R22

R10

P5

PB1

PB2

PB3

R49

C6

R93

R90

U5

R62

R61

R60

R5

R25

R9

R23

R51

R19

R17

R13

R20

R18

R14

STOP

CLOSE

OPEN

R7

R6

R16

R15

R11

R12

POWER

C24

R85

U1

C2

R

O

1

D8

U4

C

11

R

30

R

26

R

29

C3

C1

C8

R47

R84

R95

SW1

R83

R82

R33

R34

R2

R3

R4

C21

R21

D2

R65

C10

D3

C9

TR4

TR2

R52

C14

TR1

R48

C13

TR3

R89

Q1

C7

D1

D12

R28

R27

C16

LD3

LD2

P2

P3

R1

C30

P1

R31

P6

R57

COM

CL

O

S

E

ST

OP

NO

R

E

V

NC

RE

V

PH

O

T

O

COM

SINGL

E

IL

O

C

K

24

V

A

C

COM

Figure 14

Settable

Switches

Location

Operating Mode Switch 1 Switch 2 Switch 3 Switch 4

C2 Operation

OFF

OFF

OFF

OFF

B2 Operation

ON

OFF

OFF

OFF

D1 Operation

OFF

ON

OFF

OFF

E2 Operation

ON

ON

OFF

OFF

TS Operation

OFF

OFF

ON

OFF

T Operation

ON

OFF

ON

OFF

SETTING THE SWITCH SELECTABLE OPERATING MODES

OPERATION & ADJUSTMENT INSTRUCTIONS

16

Advertising
This manual is related to the following products: