INSTALLATION

DANGER

THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED.
FAILURE TO GROUND THE APPLIANCE COULD RESULT IN
ELECTROCUTION AND DEATH.

WARNING

INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED
TO WORK WITH ELECTRICITY. IMPROPER INSTALLATION CAN CAUSE
INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE
INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.

NOTICE

The data plate is located behind the access panel in the back of the griddle.
The griddle voltage, wattage, serial number, wire size, and clearance
specifications are on the data plate. This information should be carefully
read and understood before proceeding with the installation.

NOTICE

The installation of any components such as a vent hood, grease extractors,
fire extinguisher systems, must conform to their applicable National, State
and locally recognized installation standards.

4.1 Electrical Connection

There is one power supply connection on the griddle. Refer to the power supply
chart on the bottom of this page for proper power supply size.
The installer will provide a knockout location in the rear or the bottom of the
griddle.
Use a supply wire suitable for at least 90

° C.

4.2 Griddle Voltage

The model CLGPB-36A-S griddle is shipped from the factory wired for 440 volts.

4.3 Phasing

All griddles are shipped from the factory set up for a three-phase service.

GRIDDLE SPECIFICATIONS

NOMINAL AMPS PER LINE

WEIGHT

THREE PHASE

440 VOLT

MODEL

NUMBER

TOTAL

kW

LINE 1

LINE 2

LINE 3

CLG-36PB-S

18.0

21.7

21.7

21.7

405 lbs.