THERMOSTATS

FIGURE 3

7- On Robertshaw 7200 gas valve, depress lever on

gas control and move to ON and release. For White

Rodgers 36E gas valves, move switch to ON.

8- Replace unit access panel.

9- Turn on all electrical power to unit.

10- Set thermostat to desired setting. See figure 3.

11- If the furnace will not operate, follow the instructions

“To Turn Off Gas To Unit” and call your service techni-

cian or gas supplier.

B-To Turn Off Gas To Unit

1- Set thermostat to lowest setting. See figure 3.

2- Turn off all electrical power to unit if service is to be

performed. See figure 4.

3- Remove heat section access panel.

4- On Robertshaw 7200 gas valve, depress lever on

gas control and move to OFF and release. For White

Rodgers 36E gas valves, move switch to OFF.

5- Replace unit access panel.

FIGURE 4

FOR UNIT TO

OPERATE DISCONNECT

SWITCH MUST

BE IN “ON” POSITION

TYPICAL

FUSE/DISCONNECT

SWITCH BOX MOUNTED

ON FURNACE

FIGURE 5

GAS PIPING

HORIZONTAL APPLICATION

GROUND

JOINT UNION

MANUAL MAIN

SHUT--OFF VALVE

GAS

CONNECTOR*

GAS VALVE

UNIT

REAR PANEL

MANUAL MAIN

SHUT--OFF VALVE

GAS CONNECTOR*

GAS VALVE

GROUND JOINT

UNION

GAS PIPING

DOWNFLOW APPLICATION

*Gas connector may be
used

for

Canadian

installation if acceptable
by local authority having
jurisdiction.

6(59,&,1* ),/7(5

Inspect and clean air filters each month. Filters must
be cleaned when dirty to assure proper furnace op-
eration and maintain efficiency.

A-Cleaning Reusable Foam Filter

1- Turn off electrical power to furnace.

2- Remove blower access panel. Wait for blower to stop.

3- Remove filter by sliding up and out of channel.

4- Wash filter with water and a mild detergent. For in-

creased efficiency, filter media should be sprayed
with Filter Handicoater when dry. Filter Handicoater
is RP products No. 418 and is available as Lennox
part No. P-8-5069. If replacement filters is needed,
use Lennox part no. P-8-7831 for 20” x 25” (508 x
635mm) filter.

5- Reinstall filter. Slide filter into top channel and drop

into lower channel.

IMPORTANT-Do not replace foam reusable filters
with throw-away type filters.

6- Replace blower access panel.