N in table 12, Configuring a dial-in user – Lucent Technologies PortMaster User Manual
Page 197

Using ISDN BRI
12-13
ISDN BRI Unnumbered IP Configuration Example
Table 12-5
ISDN Port Values
All the other parameters should be left at their default values.
After you configure the ISDN BRI port as shown in Table 12-5, enter the following
commands to reset the ports and save the configuration:
Command> reset s1
Command> reset s2
Command> save all
For more information about synchronous ports, refer to Chapter 6, “Configuring a
Synchronous WAN Port.”
Configuring a Dial-In User
A user account must be set up on the PortMaster router in Denver so that PortMaster in
San Francisco can dial in when traffic is queued. The new user sf should be configured
with the values shown in Table 12-6.
Setting
Command
Port type S1
set s1 network twoway
Port type S2
set s2 network twoway
Dial group S1
set s1 group 2
Dial group S2
set s2 group 2
Directory number S1
set s1 directory number 5551111
Directory number S2
set s2 directory number 7005551112
SPID S1
set s1 spid 700555111100
SPID S2
set s2 spid 700555111201
Table 12-6
User Table Values
Setting
Command
Username
add netuser sf
Password
set user sf password anypasswd
Protocol
set user sf protocol ppp