Alter concept sr t8, Performance, Coefficients of utilization – Lightolier Alter Concept SR T8 User Manual

Page 2: Distribution candlepower curve 217, Candlepower, Lightolier, Canlyte

Advertising
background image

Alter Concept SR T8

Page 2 of 2

2' x 2' semi-recessed direct/indirect fluorescent

Job Information

Type:

Lightolier is a Philips group brand

Lightolier

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2008 Philips Group • QCJ2x2PFOP.pdf

Canlyte

www.canlyte.com

3015 Louis-Amos, Lachine, Québec H8T 1C4 • (514) 636-0670 • (514) 636-0460

ZONE

DEG

ALONG 22.5

45

67.5

ACROSS

0

607

607

607

607

607

5

605

603

605

608

606

10

594

596

600

600

603

15

579

583

588

591

596

20

560

565

572

578

583

25

538

541

554

563

568

30

506

513

530

544

550

35

468

480

500

519

527

40

429

443

471

494

504

45

384

402

437

465

477

50

338

358

400

429

439

55

285

313

360

392

406

60

233

262

316

356

373

65

181

215

270

318

332

70

133

170

231

272

282

75

90

123

179

196

196

80

50

80

109

110

106

85

18

34

44

55

57

90

0

5

18

30

33

COEFFICIENTS OF UTILIZATION

ZONAL CAvITY METHOD * EFFECTIvE FLOOR CAvITY REFLECTANCE = .20

80

70

50

Wall Reflectance

70 50 30 10 70 50

30 10 50 30

10

0 .82 .82 .82 .82 .80 .80 .80 .80 .76 .76 .76

1 .75 .71 .68 .66 .73 .70 .67 .65 .67 .65 .63

2 .68 .62 .58 .54 .66 .61 .57 .53 .58 .55 .52

3 .62 .55 .49 .45 .60 .54 .48 .44 .52 .47 .44

4 .57 .48 .42 .38 .55 .47 .42 .37 .46 .41 .37

5 .52 .43 .36 .32 .50 .42 .36 .31 .40 .35 .31

6 .47 .38 .32 .27 .46 .37 .31 .27 .36 .31 .27

7 .44 .34 .28 .24 .42 .34 .28 .23 .32 .27 .23

8 .40 .30 .25 .20 .39 .30 .24 .20 .29 .24 .20

9 .37 .28 .22 .18 .36 .27 .21 .18 .26 .21 .17

10 .34 .25 .19 .15 .33 .24 .19 .15 .24 .19 .15

DETERMINED IN ACCORDANCE WITH CuRRENT IES PuBLISHED PROCEDuRES

LuMINAIRE INPuT WATTS = 31.2

Room Cavity Ratio

ZONE

LUMENS

% LAMP

% LUMINAIRE

0-30

478

17.08

24.91

0-40

790

28.23

41.18

0-60

1438

51.38

74.94

0-90

1919

68.56

100.00

40-90

1129

40.33

58.82

60-90

481

17.18

25.06

90-180

0

.00

.00

0-180

1919

68.56

100.00

DISTRIBUTION

CANDLEPOWER CURVE 217

Performance

CANDLEPOWER

REPORT NO: LSCD103
CAT. NO: QCJ2GPFOP217

2 17W T8 Fluorescent Lamps at 1400 lumens.

Efficiency: 68.6%

Candela at Nadir: 607cd

90°

90°

180°

200

400

600

Advertising