INPUT FUSE AND SUPPLY WIRE
CONSIDERATIONS

Refer to the Technical Specifications at the beginning
of this Installation section for recommended fuse and
wire sizes. Fuse the input circuit with the recommend-
ed super lag fuse or delay type breakers (also called
“inverse time” or “thermal/magnetic” circuit breakers).
Choose an input and grounding wire size according to
local or national electrical codes. Using fuses or cir-
cuit breakers smaller than recommended may result in
“nuisance” shut-offs from welder inrush currents, even
if the machine is not being used at high currents.

INPUT VOLTAGE RECONNECT
PROCEDURE

Only a qualified electrician should connect the input
leads to the Power Wave. Connections should be
made in accordance with all local and national electri-
cal codes and the connection diagram located on the
inside of the reconnect/input access door of the
machine. Failure to do so may result in bodily injury or
death.

------------------------------------------------------------------------

Welders are shipped connected for the highest input
voltage listed on the rating plate. To move this con-
nection to a different input voltage, refer to reconnect

instructions located on the inside of the input access
door or in Figure A.1. If the main reconnect switch is
placed in the wrong position, the welder will not pro-
duce output power. If the Auxiliary (“A”) lead is placed
in the wrong position, there are two possible results.
If the lead is placed in a position higher than the
applied line voltage, the welder may not come on at
all. If the Auxiliary (“A”) lead is placed in a position
lower than the applied line voltage, the welder will not
come on, and the two circuit breakers in the reconnect
area will open. If this occurs, turn off the input volt-
age, properly connect the “A” lead, reset the breakers,
and try again.

OUTPUT CONNECTIONS

Use the largest welding (electrode and ground) cables
possible — at least 2/0, 4/0 preferred, copper wire —
even if the average output current would not normally
require it. When pulsing, the pulse current can
exceeds 650 amps. Voltage drops can become
excessive, leading to poor welding characteristics, if
undersized welding cables are used.

To avoid interference problems with other equipment
and to achieve the best possible operation, route all
cables directly to the work or wire feeder. Avoid
excessive lengths, bundle the electrode and ground
cables together where practical, and do not coil
excess cable.

FIGURE A.1 - CONNECTION DIAGRAM ON RECONNECT/INPUT ACCESS DOOR

200-208V

220-230V

380-415V

440-460V

200-208V

220-230V

VOLTAGE=220-230V

220-230V

200-208V

220-230V

380-415V

440-460V

200-208V

U / L1

440-460V

380-415V

.

inspecting or servicing machine.

Do not operate with covers

.

removed.

Do not touch electrically live parts.

.

Only qualified persons should install,

use or service this equipment.

.

’A’

’A’

VOLTAGE=380-415V

’A’

S23847

VOLTAGE=200-208V

THE LINCOLN ELECTRIC CO. CLEVELAND, OHIO U.S.A.

A

’A’

VOLTAGE=440-460V

CR1

W / L3

V / L2

380-415V

440-460V

Disconnect input power before

INPUT SUPPLY CONNECTION DIAGRAM

NOTE: Turn main input power to the machine OFF before performing reconnect procedure. Failure to do
so will result in damage to the machine. DO NOT switch the reconnect bar with machine power ON.

WARNING

S24196

THE LINCOLN ELECTRIC CO. CLEVELAND, OHIO U.S.A.

550-575V

VOLTAGE=440-460V

VOLTAGE=550-575V

’A’

’A’

A

440-460V

.

inspecting or servicing machine.

U / L1

Disconnect input power before

.

Do not operate with covers

removed.

V / L2

.

Do not touch electrically live parts.

CR1

W / L3

INPUT SUPPLY CONNECTION DIAGRAM

.

use or service this equipment.

Only qualified persons should install,

440-460V

550-575V

Advertising