Lucent Technologies MN10285K User Manual

Page 168

Advertising
background image

On-Screen Display

VRAM

MN102H75K/F75K/85K/F85K LSI User Manual

Panasonic Semiconductor Development Company

167

Panasonic

CHP: Character Horizontal Position Control Code

ID Code: 11

CHSZ[1:0]

Specifies the H size of the characters on the next line.

00: 1 dot = 1 VCLK period
01: 1 dot = 2 VCLK periods

10: 1 dot = 3 VCLK periods
11: 1 dot = 4 VCLK periods

CSHT

Specifies shutter operation for the next line. Setting this bit to 1 disables

the shuttering function. You can disable and enable shuttering on a line-by-
line basis.

0: Enable
1: Disable

CHP[9:0]

Specifies a VCLK indicating the horizontal start position for the next line.
1024 steps are available.

CVP: Character Vertical Position Control Code

ID Code: 11

CLAST

Specifies the last line in the internal RAM text layer. This resets the line

pointer for character reads from the internal RAM to the first line.

0: Disable

1: Enable

In closed-caption mode, only the

b’00’, b’01’, and b’11’ settings

are available for CVSZ[1:0]. The
b’10’ setting is reserved.

CVSZ[1:0]

Specifies the V size of the characters on the next line.

00: 1 dot = 1 H scan line

01: 1 dot = 2 H scan lines
10: 1 dot = 4 H scan lines

11: 1 dot = 6 H scan lines

CINT

Specifies an OSD interrupt.

0: Disable
1: Enable

CVP[9:0]

Specifies an H scan line indicating the vertical start position for the next

line. 1024 steps are available.

Graphics Layer
GTC:
Graphic Tile Code

ID Code: 00

GCBF

Repeat blank/repeat tile select.

0: Repeat blank

1: Repeat tile

Advertising
This manual is related to the following products: