Lytecaster, Recessed downlighting, Lighting data – Lightolier 1195 User Manual

Page 2: Job information type, Lightolier, Units 2 feet from wall, Units 3 feet from wall

Advertising
background image

Lytecaster

®

Recessed Downlighting

1195

Page 2 of 2

6 3/4" Aperture Deep Wall Washer Reflector Trim

Job Information

Type:

Lightolier

a Genlyte company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • I1007

Candlepower Curve

3’

3’

2’

3’

12 f.c.

17 f.c.

Lighting Data

Example: With clear Alzak

®

and 150W A-21

units, located 3’ from wall and 5’ on center,
(matching downlights 5’ on center), the
illumination on the wall 3’ down from the
ceiling is 19 f.c. beneath and 13 f.c. between
fixtures.

Lighting Data

Example: With clear Alzak

®

and 32W TTT units,

located 3’ from wall and 5’ on center, (matching
downlights 5’ on center), the illumination on the
wall 3’ down from the ceiling is 17 f.c. beneath
and 12 f.c. between fixtures.

3’

3’

2’

3’

19 f.c.

13 f.c.

DIST

ANCE

FROM

CEILING

, FT

.

UNITS 2 FEET FROM WALL

Footcandle values are averaged and rounded off and are based on a minimum of
five units.

Footcandle values are averaged and rounded off and are based on a minimum of
five units.

2’

DOWNLIGHT SPACING RATIO = 1.2

Report 1198FR

Efficiency = 55.0%

Footcandles on Wall From Multiple Units: 32W TTT Specular Clear

Footcandles on Wall From Multiple Units: 32W TTT Specular Clear

Lighting Data

Down

Wall

DOWNLIGHT SPACING RATIO = 1.1

COEFFICIENTS OF UTILIZATION

% EFFECTIvE CEILING CAvITy REFLECTANCE

80

70

50

30

10

0

0
.50

.45

.41

.37

.33

.29

.26

.23

.21

.19

ROOM

CA

vIT

y

RA

TIO

20% FLOOR CAvITy REFLECTANCE

50 30 10

50 30 10

50 30 10

50 30 10

50 30 10

1 .61 .59 .57

.60 .58 .56

.57 .56 .55

.55 .54 .53

.53 .52 .51

2 .55 .52 .50

.54 .52 .49

.52 .50 .48

.51 .49 .47

.49 .48 .46

3 .50 .47 .44

.49 .46 .44

.48 .45 .43

.46 .44 .42

.45 .43 .42

4 .46 .42 .39

.45 .42 .39

.44 .41 .39

.43 .40 .38

.42 .39 .38

5 .42 .38 .35

.41 .38 .35

.40 .37 .34

.39 .36 .34

.38 .36 .34

6 .38 .34 .31

.38 .34 31

.37 .34 .31

.36 .33 .31

.35 .32 .30

7 .35 .31 .26

.34 .31 .28

.34 .30 .28

.33 .30 .27

.32 .29 .27

8 .32 .28 .25

.31 .28 .25

.31 .27 .25

.30 .27 .25

.30 .27 .24

9 .29 .25 .22

.29 .25 .22

.28 .25 .22

.28 .24 .22

.27 .24 .22

10 .27 .23 .20

.26 .23 .20

.26 .22 .20

.25 .22 .20

.25 .22 .20

% WALL REFLECTANCE

FOR 26WTTT, MULTIPLY C.U.’S BY 1.15.

COEFFICIENTS OF UTILIZATION

% EFFECTIvE CEILING CAvITy REFLECTANCE

80

70

50

30

10

0

0
.51

.47

.43

.39

.36

.33

.30

.28

.25

.23

ROOM

CA

vIT

y

RA

TIO

20% FLOOR CAvITy REFLECTANCE

50 30 10

50 30 10

50 30 10

50 30 10

50 30 10

1 .60 .59 .58

.59 .58 .57

.57 .56 .55

.55 .54 .53

.53 .52 .52

2 .56 .54 .51

.55 .53 .51

.53 .51 .50

.51 .50 .49

.50 .49 .48

3 .51 .49 .46

.51 .48 .46

.49 .47 .45

.48 .46 .44

.47 .45 .44

4 .48 .45 .42

.47 .44 .42

.46 .43 .41

.45 .43 .41

.44 .42 .40

5 .44 .41 .38

.44 .40 .38

.43 .40 .38

.42 .39 .37

.41 .39 .37

6 .41 .37 .35

.41 .37 .35

.40 .37 .34

.39 .36 .34

.38 .36 .34

7 .38 .34 .32

.37 .34 .31

.37 .34 .31

.36 .33 .31

.35 .33 .31

8 .35 .31 .29

.35 .31 .29

.34 .31 .29

.33 .31 .29

.33 .30 .28

9 .32 .29 .26

.32 .29 .26

.31 .28 .26

.31 .28 .26

.30 .28 .26

10 .30 .26 .24

.30 .26 .24

.29 .26 .24

.29 .26 .24

.28 .26 .24

% WALL REFLECTANCE

FOR 100W A19, MULTIPLY C.U.’s BY 1.1.

3’

4’

32

16

32

34

20

34

23

21

23

16

16

16

11

13

12

9

10

9

7

7

7

6

6

6

5

5

5

36

28

36

39

31

39

29

29

29

21

22

21

15

16

15

12

12

12

9

9

9

7

7

7

6

6

6

48

46

48

54

51

54

43

43

43

31

32

31

22

23

22

16

16

16

12

12

12

9

9

9

7

7

7

1
2
3
4
5
6
7
8
9

DIST

ANCE

FROM

CEILING

, FT

.

UNITS 3 FEET FROM WALL

3’

5’

11

8

11

17

12

17

17

12

17

14

12

14

11

11

11

9

9

9

7

8

7

6

6

6

5

5

5

4’

12

11

12

19

17

19

19

16

19

16

16

16

13

14

13

11

11

11

9

9

9

7

8

7

6

6

6

16

15

16

24

23

24

24

23

24

21

21

21

18

18

18

14

15

14

11

12

11

9

9

9

8

8

8

1
2
3
4
5
6
7
8
9

DIST

ANCE

FROM

CEILING

, FT

.

UNITS 2 FEET FROM WALL

2’

Footcandles on Wall From Multiple Units: 150W A-21 Specular Clear

3’

4’

30

11

30

40

21

40

28

26

28

18

23

18

14

17

14

12

13

12

10

10

10

8

8

8

7

7

7

32

22

32

44

35

44

33

30

33

26

29

26

20

21

20

16

16

16

13

13

13

10

10

10

9

9

9

41

39

41

60

60

60

53

54

53

40

41

40

30

30

30

23

23

23

17

18

17

14

14

14

11

11

11

1
2
3
4
5
6
7
8
9

DIST

ANCE

FROM

CEILING

, FT

.

UNITS 3 FEET FROM WALL

3’

Footcandles on Wall From Multiple Units: 150W A-21 Specular Clear

4’

5’

9

5

9

17

11

17

19

13

19

16

15

16

13

15

13

10

12

11

9

10 9

8

8

8

7

7

7

11

10

11

23

23

23

27

27

27

25

26

25

22

22

22

18

19

18

15

15

15

13

13

13

11

11

11

1
2
3
4
5
6
7
8
9

Candlepower Curve

Report 1227FR

Efficiency = 56.0%

Down

Wall

10

7

10

18

16

18

22

19

22

19

20

19

16

18

16

14

14

14

12

12

12

10

10

10

9

9

9