Using the Biggest Quadra

5.2.3. Failure and Error Messages

■

These messages will be displayed in the event of a

RAID or disk failure, or an error during a process.

RAID Failure Messages

LCD Display

Message

Message Cleared When...

RAID Fail

code: 0

The RAID array failed. There are not

enough disks for the RAID array to

operate.

A disk is re-installed

❖

RAID Fail

code: 1 <---->

The RAID array failed. The sequence

of the disks in the array is incorrect.

The current sequence is displayed

within the “<---->” space.

The original disk sequence is

restored

❖

RAID Fail

code: 2

The RAID array failed but all original

disks are existing after restarting the

unit.

The RAID array is recreated.

❖

Disk Failure Message

LCD Display

Message

Message Cleared When...

DISK x Fail

Disk “x” failed.

The failed disk is replaced

❖

Fan Failure Message

LCD Display

Message

Message Cleared When...

FAN Fail

xxxx rpm

Fan failure. xxxx rpm = the current

speed of the fan

The failed fan is repaired or replaced

❖