NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Periodically (After the Burning Season)

Maintenance Task

Accomplishing Person

Procedure

Cleaning Firebox Interior

Check Flame Patterns and Flame Height

Checking Vent System

Cleaning Glass Enclosure Panels

Homeowner

Homeowner

Homeowner

Homeowner

Carefully remove logs, vermiculite and black and
gray ceramic fiber chunks. Vacuum out interior of
the firebox. Clean firebox walls and log grate.
Replace logs, vermiculite and black and gray ce-
ramic fiber chunks as detailed on

page 8.

Maintenance Task

Accomplishing Person

Procedure

Inspecting/Cleaning Burner, Logs
and Controls

Check Flame Patterns and Flame Height

Inspecting/Cleaning Pilot Burner and the Two
Main Burners

Checking Vent System

Appliance Checkout

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Inspect valve and ensure it is properly operat-
ing. Check piping for leaks. Vacuum the con-
trol compartment, fireplace logs and burner
area.

Refer to

Figure 8 on page 8 and verify that the

flame pattern and height displayed by the
appliance conforms to the picture. Flames
must not impinge on the log set.

Refer to

Figure 1 on page 8 (SIT) or Figure 12

on page 9 (Honeywell). Remove any surface
build-up on pilot and burner assembly. Clean the
pilot nozzles, ignitor/flame rod and hood with a
soft brush. Ensure the pilot flame engulfs the
flame sensor as shown.

Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage
or obstruction. Look for any signs of disloca-
tion of the vent components.

Perform the appropriate appliance checkout
procedure detailed in this manual.

Maintenance Schedule

Annually (Before the onset of the Burning Season)

Clean as necessary following the directions
provided in this manual. DO NOT TOUCH OR
CLEAN GLASS WHILE IT IS HOT
.

Inspect the vent system at the top and at the
base (within the firebox) for signs of block-
age or obstruction. Look for any signs of
dislocation of the vent components.

Refer to

Figure 8 on page 8 and verify that

the flame pattern and height displayed by the
appliance conforms to the picture. Flames
must not impinge on the log set.