External device connections – LG LVC-SX703PB/OB/MB User Manual

Page 14

Advertising
background image

14

External Device Connections

RS-485 Connection

Connect to an external controller of RS-485 format.

Alarm Connection

Connect an external device such as a buzzer or
lamp to the ALARM terminal. When the camera
detects motion, the alarm output signal is supplied
to the connected external device.

Contact Ratings
• Maximum load current is ±130mA.
• Do not connect any system or

device that has over 40 Vp-p
(DC 30 V) bias voltage on the
contact terminal.

Notes:
Use a relay unit if the voltage or current of the
connected device exceeds the ratings.

Multi-Input Connection

Connect an external device to use HOT KEY func-
tion. The HOT KEY function is operated when the
input signal is “ON”. To set the HOT KEY function,
see page 35.
The Multi-Input terminal has the register of DC
3.3V pull-up. The sink current must be less than
0.8mA.
OFF: Open contact
ON: Closed contact

RS-485 (TR+)

RS-485 (TR-)

ALARM (OUT)

ALARM (COM)

MULTI (INPUT)

MULTI (GND)

ALARM

COM

Equivalent Diagram