Troubleshooting, 1. before performing service, 2. qc test mode – LG WD(M)-80130F User Manual

Page 15

Advertising
background image

7. TROUBLESHOOTING

7-1. BEFORE PERFORMING SERVICE

Be careful of electric shock or disconnecting the parts while troubleshooting.

Voltage of each terminal in 220-240V~ and DC while applying an electric current.

7-2. QC TEST MODE.

Pressing Temp, and Option button simultaneously.

Power supply ON with pressing upper two button.

Press the START/PAUSE button as follows.

Press the START/PAUSE button more 4 times until stop spinning

Pressing number of

START/PAUSE button

Checking Point

None

All lamps turn on

1 time

Clockwise spin (right)

2 times

Low speed spin

3 times

High speed spin

4 times

Inlet valve for pre-wash operation

5 times

Inlet valve for main-wash operation

Hot inlet valve in case of hot water fill

6 times

Inlet valve for main-wash operation

7 times

Counterclockwise spin (left)

8 times

A Heater is in operation for 3 sec.

9 times

Draining pump operation

10 times

Auto off operation

Temp.

Option

15

Advertising