TROUBLESHOOTING & REPAIR

F-53

F-53

FIGURE F.22 – 3/16” ALLEN BOLT LOCATION

- +

- +

- +

- +

3/16" ALLEN BOLTS

MAIN SWITCH BOARD REMOVAL & REPLACEMENT (continued)

9. Using a 3/16” allen wrench remove four allen

bolts and washers as shown in Figure F.22.
At this point, the board is ready for removal.

10. Carefully maneuver the board out of the

machine.

11. Apply a thin coat of Penetrox A-13 to the

IGBT heatsinks on the back of the new
switch boards mating surfaces. Note: Keep
compound away from the mounting holes.

12. Replace the four allen bolts and washers

previously removed.

13. Replace the eight capacitor terminal nuts,

washers, and necessary leads previously
removed.

14. Reconnect the three harness plugs previous-

ly removed.

15. Reconnect the nine leads (#201-#209) that

were previously removed.

16. Replace any necessary cable ties previously

removed.

17. Pre-torque all screws to 25 inch lbs. before

tightening to 44 inch lbs.

18. Replace the input lead shield previously

removed.

19. Replace the case wraparound cover.