Vra2g9ls26u, Vr parabolic, Options & accessories – Lightolier VR Parabolic VRA2G9LS26USO User Manual

Page 2: Specifications, Specifications (continued), Photometry, Ordering information, Job information type, Lightolier

Advertising
background image

VR PARABOLIC

VRA2G9LS26U

Page 2 of 2

2'x2' RECESSED FLUORESCENT, 4" DEEP, 9 CELL (3x3) PARABOLIC LOUVER

AIR SUPPLY/RETURN/HEAT EXTRACTION, IES RP1 FOR NORMAL VDT USE

Lightolier

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902

SECTION 2/Folio G05-40 REV. A

Job Information

Type:

OPTIONS & ACCESSORIES

PLASTER FRAME: Catalog Number: PF22.
CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are
required between fixtures, Order Catalog Number: S2FCTRIM (each joint).
SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM.
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture
standard. SUFFIX: RF.
ELECTRICAL WIRING OPTIONS: Consult factory.
AIR CLOSURE STRIPS: SUFFIX ACS2 (factory installed).
DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10.)
CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less
than .62 with a spacing to mounting ratio of 1.3 perpendicular to the lamps. To
meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba-
bility) shall not be less than 93 either crosswise or lengthwise and the maximum
average brightness at 65°, 75° and 85° shall not exceed 357, 130, and 38 cande-
las per square meter respectively in the 0°, 45°, and 90° horizontal planes.
Candelas at Nadir (0°) not to exceed 1521.

SPECIFICATIONS (continued)

AIR HANDLING: (VRA only) side air passages for air supply or air return.
Optional side closure strips. Air return is also provided through the lamp com-
partment through fixture body ends.
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel.
Housing side rails hemmed over and housing ends turned-in for safe handling.
LOUVER: Pre-anodized aluminum (Coilzak@ or equal).
FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked
polyester enamel minimum 86% reflectance. Phosphate undercoating.
Louver–low iridescence semi-specular anodized vertical grain aluminum reflec-
tor sheet is standard.
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and C-UL.

PHOTOMETRY

MODEL NO. VRA2G9LS26USO

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

64

62

60

58

57

56

56

55

54

2

59

56

53

53

51

49

51

49

48

3

55

50

47

48

45

43

47

44

42

4

51

46

42

44

40

38

42

40

37

5

48

41

37

40

36

33

39

36

33

6

44

38

33

36

33

30

35

32

30

7

42

34

30

33

29

27

32

29

27

8

38

32

27

30

27

24

30

26

24

9

36

29

25

28

24

22

28

24

22

10

34

27

23

26

22

20

26

22

20

visual comfort probability (rated lumens per lamp 3150.)

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

91

85

77

77

92

90

85

76

20

30

92

87

81

77

92

90

88

81

20

40

92

89

84

80

92

90

88

84

20

60

92

89

86

82

92

91

88

84

30

20

91

85

81

78

92

91

87

77

30

30

92

88

84

78

92

91

89

81

30

40

92

89

87

81

92

91

89

83

30

60

92

89

88

83

92

91

89

84

30

80

93

90

88

83

92

90

89

84

40

20

91

85

81

81

92

91

87

79

40

30

92

88

84

81

92

91

89

83

40

40

92

89

87

83

92

91

89

85

40

60

93

90

88

85

93

90

89

84

40

80

93

90

88

85

93

90

89

84

40

100

93

90

88

85

93

90

89

84

60

30

92

83

84

81

92

91

89

83

60

40

93

90

87

83

92

90

89

84

60

60

93

90

88

85

93

90

89

84

60

80

93

90

88

85

93

90

89

83

60

100

93

90

88

85

93

90

89

83

100

40

93

90

87

83

93

90

89

84

100

60

93

90

88

85

93

90

89

83

100

80

93

90

88

85

93

90

89

84

100

100

93

90

88

85

93

90

89

84

ro

om cavity ratio

luminaries lengthwise

luminaries cr

osswise

ORDERING INFORMATION

Explanation of Catalog Number. Example: VRA2G9LS26U120SOGLR

LER = FP - 47.8

IW - 59.2

BF - 93.6

Comparative yearly lighting energy cost per 1000 lumens = $5.02

VR

VR:

4" Deep

Pre-anodized

Aluminum

Louver

For Normal

VDT Use

BODY STYLE:

A=Air Handling
S=Static

2

FIXTURE

WIDTH

CEILING TYPE:

G= Grid

(lay-in T bar)

F=Flanged

(overlap)

Z spline and
plaster

frame

T=Slot grid or

two-directional
concealed
T (see options)

9

NUMBER OF

CELLS:

(3 rows of

3 cells)

LOUVER

FINISH*:

L=Low

Iridescence
Semi-specular
(standard)

P=Low

Iridescence
Specular

S

SINGLE “V”
REFLECTOR

2

LAMP

QUANTITY

6U

LAMP TYPE/

FIXTURE
LENGTH:

6"U LAMP

T8 OR T12

(Nominal 24")

VOLTAGE:

120 or 277

OPTIONS:

Add appropriate
suffix to catalog

no, ie: (GLR)

BALLAST TYPE:

1-2 Lamp Mag. T12

LE

<

20THD

<

10THD

1-2 Lamp Elec. T8

SO*

H

I

*

LOL T8 Dimming

PS

*Instant Start Standard

Other dimming options consult factory.

Advertising