Xp/xa series, Lens recessed, Lightolier is a philips group brand – Lightolier XA Series User Manual

Page 2: G2 ft va 2, Ordering information, Options/accessories, Specifications, Specifications (continued), Photometry, Job information type

Advertising
background image

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 a Philips Group

Section 1A/Folio F60-55 Rev. A

Job Information

Type:

Lightolier is a Philips group brand

XP = Recessed

Fluorescent
with Flat Steel
Lens Frame

XA = Recessed

Fluorescent
with Regressed
Aluminum
Lens Frame

Fixture Width

Ceiling Type:

G = Grid (lay-in)

T-bar

Lamp Fixture Length:

FT = Twin Tube (T5)

(Nominal 24")

Voltage:

120, 277 or

UNV=120-277

Lens Shielding

Type:

VA = Virgin Acrylic

(standard) see
options and
consult factory

Lamp

Quantity:

(By others)

2 = 2 Lamp

Ballast Type:

<

20THD

<

10THD

1-2 Lamp Elec. (TT5)

SB*

IB*

LOL TT5 Dimming

PB

*Instant Start Standard
Other dimming options. Consult factory.

G

2

FT

VA

2

Options:

Lamps
Flex
Fuse

(Consult your

representative)

Ordering Information

Explanation of Catalog Number. Example: XP2GVA2FT120SBGLR

-

Lens Recessed

XP/XA Series

Page 2 of 2

Static, 2' x 2', Recessed Fluorescent, Flat Steel Lens Frame (XP)

Regressed Aluminum Lens Frame (XA), 2 Lamp TT5

Options/Accessories

Special Lens: Substitute VY for .125" nominal pattern 12 with 7.8 oz. average weight per
square foot. Substitute VI for .125" normal pattern 12 with 6.8 oz. average weight per
square foot.
Access Plates: Top wiring access plate is shipped with fixture as
standard. When access plates are required in advance for wiring
convenience, specify separately. Order Catalog Number: ACP CSP.
Electrical Wiring Options: Consult factory.
Fusing:

Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture: Suffix: R. One per
ballast: Suffix: B.
Drywall Kit: G type fixtures for drywall or plaster ceilings. Order Catalog Number: FK92X2.

Specifications

Performance: In an installation of 2 lamps 40 W luminaires in a room cavity ratio of 1,
with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .89.
To reduce glare the VCP shall not be less than 37 either lengthwise or crosswise (at 100 fc
level) and the average brightness at 65 shall not exceed 3956 footlamberts. To control veil-
ing reflections, luminaire output in the 30°-90° zone shall be not less than 68%.

Specifications (continued)

Materials: Chassis parts are die-formed code gauge cold rolled steel. Lens frames
(XP) flat full-size steel frame, (XA) regressed full-size aluminum frame.
Finish: Chassis exterior—white baked polyester enamel. Cavity—white baked polyester
enamel minimum 86% reflectance. Phosphate undercoating.
Lens: Extruded virgin acrylic 3/16" square based female cones, running 45° to the panel
edge. .095" nominal thickness (similar to pattern 12).
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with-
in 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws.
See: www.lamprecycle.org

Photometry

Model No. XP2GVA2FT120SB

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

92

85

89

83

81

78

80

78

76

2

85

78

73

74

70

66

71

68

65

3

78

69

63

66

61

56

63

59

55

4

72

62

55

59

53

49

57

52

48

5

66

56

49

53

47

43

52

46

42

6

61

51

43

48

42

38

47

42

37

7

57

46

39

44

38

34

43

37

33

8

53

42

35

40

34

30

39

34

30

9

50

39

32

37

31

27

36

31

27

10

47

36

29

35

29

25

34

29

25

visual comfort probability (rated lumens per lamp 2850.)

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

53

57

65

74

51

55

62

70

20

30

46

50

54

62

43

47

52

59

20

40

43

45

49

54

39

42

46

51

20

60

40

42

45

49

35

38

41

45

30

20

55

58

64

71

53

57

62

69

30

30

47

50

54

60

45

48

52

57

30

40

43

45

48

52

39

42

46

50

30

60

39

42

43

47

35

38

40

44

30

80

38

40

41

44

34

36

37

40

40

20

56

60

65

71

55

59

64

69

40

30

49

52

55

59

46

50

53

57

40

40

44

45

49

52

41

44

47

50

40

60

40

42

44

47

36

39

40

44

40

80

38

40

40

43

34

36

37

40

40

100

38

39

39

41

34

35

35

38

60

30

49

53

55

60

48

52

54

58

60

40

45

47

49

52

42

45

48

51

60

60

40

43

44

47

37

40

41

44

60

80

38

40

40

43

35

37

37

40

60

100

38

39

38

41

34

35

35

37

100

40

47

50

51

55

46

48

50

54

100

60

43

45

45

49

41

43

43

47

100

80

41

42

42

44

38

39

39

42

100

100

39

40

39

42

36

37

36

38

room

cavity

ratio

luminaries

lengthwise

luminaries

crosswise

LER = FL - 74.3

IW - 58

BF - 0.87

Comparative yearly lighting energy cost per 1000 lumens = $3.24

G03129

XP2GVA2FT120SB

Advertising
This manual is related to the following products: