Choosing the Best Location for the MCU

The MCU should be mounted in a dry location,
allowing enough room at the back for connecting
system cables.

The MCU should be placed so that the LCD
display is visible and the buttons are accessible to
the user.

The MCU is not susceptible to magnetic
interference and does not need to be mounted on a
level surface.

Installation

54-0198

25

FWD

38.86"

(987 mm)

4x .50"

(4x 13 mm)

35"

( 889 mm)

12"

(305 mm)

6"

(152 mm)

6"

(152 mm)

12"

(305 mm)

Access Hatch

17"

(432 mm)

Figure 2-2
Antenna Unit Dimensions

The radome exterior is treated
with a special finish selected for
compatibility with the dome material
and transparency to the satellite
signals. Application of additional
paints or finishes WILL degrade
performance, potentially beyond
acceptable limits.

A full-size template of the baseplate
mounting holes has been provided
at the back of this manual.

Four small holes have been drilled
into the bottom of the baseplate to
ensure that any moisture that
enters the antenna unit is able to
drain. Be sure these drain holes do
not become blocked.