If installing the arm on a Mobiflex 200-M,

refer to the Mobiflex 200-M manual for installation
information.

If installing the arm on a Mobiflex 400-MS,

refer to the Mobiflex 400-MS manual for installation
information.

If installing the arm with an SF2400 Fan,

refer to the SF2400 Fan manual for installation
information

This manual covers installation of a:

K1655-1 LFA 3.1, 10 ft. Arm or
K1655-2 LFA 4.1, 13 ft. Arm

on a K1657-1 Wall Mounting Bracket

If installing the arm on an Extension Crane

without a K1656-1 SF2400 Fan, refer to the Extension
Crane manual for installation information.

The installer is responsible for following local safety
codes and regulations.

------------------------------------------------------------------------

Before drilling, verify locations of existing gas, water,
or electrical conduits.

------------------------------------------------------------------------

K1655-1 LFA 3.1 or K1655-2 LFA 4.1 Arm Includes:

•

Assembled arm pieces

•

Flexible hose, (2) 8

”

Rubber seals for hood hinge

•

(2) 8

”

Rubber seals for base hinge

•

Hood assembly

•

(2) Bolts, M8x1.25, 45mm long (about 1.75

”

)

•

(2) Nuts, M8 self-locking

•

Hose running guard

•

Clamping pin for red plastic ring

•

Metal rotating hinge

•

Red plastic ring

K1657-1 Wall Mounting Bracket Includes:

•

(2) Bracket pieces

•

Hanging Adapter

•

Spring Bracket

•

Flexible Hose, (2) 8

”

Rubber bands for arm base

•

(2) Bolts, M8x1.25, 45mm long (about 1.75

”

)

•

(4) Bolts, M8x1.25, 75mm long (about 3.00

”

)

•

(6) Nuts, M8 self-locking

•

(6) Washers, M8

A-2

INSTALLATION

LFA 3.1 & 4.1 FUME EXTRACTION ARMS

A-2

Read this entire installation section before you
start installation.

SAFETY PRECAUTIONS

Do not attempt to use this equipment until you have
thoroughly read all installation, operating and mainte-
nance information supplied with your equipment. They
include important safety precautions and detailed
operating and maintenance instructions.

ELECTRIC SHOCK can kill.

•

Do not touch electrically live parts such
as internal wiring.

•

Turn the input power off at the fuse box
before working on this equipment.

•

Have a qualified person install and ser-
vice this equipment.

------------------------------------------------------------------------

MOVING PARTS can injure.

•

Do not operate with covers open or fil-
ter removed.

•

Keep away from moving parts.

------------------------------------------------------------------------

Only qualified personnel should install, use or service
this equipment.

GENERAL DESCRIPTION

Lincoln

’

s LFA extraction arms are spring-balanced for

easy positioning. They are intended for use with a
low-vacuum, high-volume extraction fan. The LFA
arms are commonly installed on a Mobiflex 200-M
mobile base unit with filter or with an SF2400 Wall-
Mounted Extraction Fan, with or without a Statiflex
200-M Wall-Mounted Filter Unit. Extension Cranes are
available in 7 ft. and 14 ft. lengths, with an optional
Feeder Hanging Rail. Lamp Kits available for both the
Mobiflex and Wall-Mounted Systems provide hood-
mounted switches for the light and connected fan sys-
tem. An Automatic Start/Stop Arc Sensor can be
installed with either lamp kit to automatically start the
connected extraction system (Mobiflex 200-M or
SF2400 Fan) when the sensor detects a welding arc.

Installation procedures for the K1655-1 and K1655-2,
LFA 3.1 and 4.1 Extraction Arms have been com-
bined; the difference between the arms is the length of
the arm sections, which does not affect installation
procedures.

WARNING

WARNING

Advertising