Alter tilelyte qvd, 2 x 2, Performance – Lightolier Alter QVD2GGLOP T5 User Manual

Page 2: Coefficients of utilization, Distribution candlepower curve 3ft, Candlepower, Distribution candlepower curve 424, Job information type

Advertising
background image

Alter

Tilelyte QVD

2 x 2

Page 2 of 2

2’ x 2’ Recessed Direct/Indirect Fluorescent

ZONE

DEG

ALONG 22.5

45

67.5

ACROSS

0

1856

1856

1856

1856

1856

5

1846

1845

1842

1847

1854

10

1814

1812

1818

1816

1820

15

1762

1760

1759

1773

1767

20

1685

1684

1695

1694

1694

25

1598

1598

1591

1596

1599

30

1481

1484

1484

1484

1489

35

1363

1361

1364

1369

1369

40

1234

1239

1234

1236

1236

45

1090

1099

1091

1091

1103

50

941

948

941

941

949

55

798

795

799

807

806

60

654

651

652

659

655

65

514

507

513

505

509

70

376

371

369

372

382

75

242

240

241

240

244

80

125

121

126

126

123

85

35

34

25

31

26

90

0

0

0

0

0

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80

70

50

Wall Reflectance

70 50 30 10 70 50

30 10 50 30

10

0 .58 .58 .58 .58 .57 .57 .57 .57 .54 .54 .54

1 .54 .52 .50 .48 .53 .51 .49 .48 .49 .47 .46

2 .50 .46 .43 .41 .49 .45 .43 .40 .44 .41 .39

3 .46 .41 .38 .35 .45 .40 .37 .35 .39 .36 .34

4 .42 .37 .33 .30 .41 .36 .33 .30 .35 .32 .30

5 .39 .33 .29 .26 .38 .33 .29 .26 .32 .28 .26

6 .36 .30 .26 .23 .35 .30 .26 .23 .29 .25 .23

7 .33 .27 .23 .20 .32 .27 .23 .20 .26 .22 .20

8 .31 .25 .21 .18 .30 .24 .20 .18 .24 .20 .18

9 .29 .22 .18 .16 .28 .22 .18 .16 .21 .18 .16

10 .27 .20 .17 .14 .26 .20 .17 .14 .20 .16 .14

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

LUMINAIRE INPUT WATTS = 99.8

Room Cavity Ratio

ZONE

LUMENS

% LAMP

%LUMINAIRE

0-30

1406

14.89

30.45

0-40

2258

23.90

48.88

0-60

3812

40.35

82.51

0-90

4620

48.90

100.00

40-90

2362

25.00

51.12

60-90

808

8.55

17.49

90-180

0

.00

.00

0-180

4620

48.90

100.00

DISTRIBUTION

CANDLEPOWER CURVE 3FT

Performance

CANDLEPOWER

REPORT NO: LSCA677
CAT. NO: QVD2GGLOP3FT120X3

3 40W TT5 Compact Fluorescent Lamps at 3150 lumens.

Efficiency: 48.9%

Candela at Nadir: 1856cd

90°

90°

180°

800

1600

2400

ZONE

DEG

ALONG 22.5

45

67.5

ACROSS

0

1315

1315

1315

1315

1315

5

1305

1303

1316

1316

1317

10

1287

1284

1286

1291

1291

15

1249

1248

1249

1251

1252

20

1200

1202

1201

1200

1206

25

1135

1132

1137

1135

1148

30

1053

1065

1060

1061

1064

35

970

975

971

980

979

40

878

882

881

891

890

45

785

779

784

783

786

50

677

680

674

683

681

55

576

572

571

578

580

60

469

477

474

477

478

65

375

372

371

370

373

70

277

276

270

273

280

75

184

182

178

181

183

80

96

92

91

96

93

85

31

20

20

20

21

90

0

0

0

0

0

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80

70

50

Wall Reflectance

70 50 30 10 70 50

30 10 50 30

10

0 .56 .56 .56 .56 .55 .55 .55 .55 .52 .52 .52

1 .52 .50 .48 .47 .51 .49 .47 .46 .47 .46 .44

2 .48 .44 .41 .39 .47 .43 .41 .38 .42 .40 .38

3 .44 .39 .36 .33 .43 .39 .35 .33 .37 .35 .32

4 .40 .35 .31 .28 .39 .35 .31 .28 .33 .30 .28

5 .37 .31 .27 .24 .36 .31 .27 .24 .30 .26 .24

6 .34 .28 .24 .21 .33 .28 .24 .21 .27 .23 .21

7 .31 .25 .21 .19 .31 .25 .21 .18 .24 .21 .18

8 .29 .23 .19 .16 .28 .22 .19 .16 .22 .18 .16

9 .27 .21 .17 .14 .26 .20 .17 .14 .20 .16 .14

10 .25 .19 .15 .12 .24 .18 .15 .12 .18 .15 .12

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

LUMINAIRE INPUT WATTS = 95.7

Room Cavity Ratio

ZONE

LUMENS

% LAMP

%LUMINAIRE

0-30

1000

14.21

30.14

0-40

1608

22.84

48.46

0-60

2725

38.72

82.14

0-90

3318

47.14

100.00

40-90

1710

24.30

51.54

60-90

592

8.42

17.86

90-180

0

.00

.00

0-180

3318

47.14

100.00

DISTRIBUTION

CANDLEPOWER CURVE 424

Performance

CANDLEPOWER

REPORT NO: LSCA934
CAT. NO: QVD2GGLOP424120PG

4 24W T5HO Fluorescent Lamps at 1760 lumens.

Efficiency: 47.1%

Candela at Nadir: 1315cd

90°

90°

180°

400

800

1200

Job Information

Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

11/10

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group

Section 5/Folio L10-10 Rev. A

Advertising
This manual is related to the following products: